verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC500 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC50020LNW

The AirTAC Airtac GAFC Air Service Unit GAFC50020LNW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size3/4"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialPC
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight1910 g
$102.72 $113.34Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC50020LNW

This GAFC50020LNW is a two-piece F.R.L. combination built for a 3/4in line. The first body houses the filter and regulator together, so air is cleaned and set to pressure in one pass before the lubricator adds a metered oil mist downstream. It regulates from 0.15 to 0.4 MPa (20-58 psi) and uses a 5 um element to catch fine particles.

The PC bowl holds 108 cc of condensate, while the separate oil bowl holds 225 cc, and the complete unit weighs 1910 g. With no gauge fitted, the 1/4in gauge connection is left open for a later addition. The lower-pressure range suits applications that never need more than 0.4 MPa, and the semi-auto drain clears water each time pressure drops.

Airtac GAFC Air Service Unit GAFC50020LNW Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC50020LNW
SeriesGAFC500 F.R.L. combination
Port size3/4" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialPC
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl108 cc
Capacity of oil bowl225 cc
Recommended lubricantISO VG 32 or equivalent
Weight1910 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC500 is 1/4" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC50020LNW

GAFC500GA500 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
20Port size 3/4". This body offers 20 = 3/4".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/4" gauge connection.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
(blank)No reverse-flow valve.

Constituent units, orderable separately as spares: GAFR500-20 filter & regulator, GAL500-20 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC500 · 3/4" · curve to 7000 L/min
One size downGAFC400
One size upGAFC600 (curve to 12000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC50020LNW Is Used

precision_manufacturing

Precision machining centers

Feed a 5 um filtered, regulated air supply to tool changers and spindle air curtains on CNC machining centers, where fine filtration protects sensitive valves.

factory

Assembly line automation

Power multi-station assembly fixtures with a 3/4in header, providing consistent lower-pressure air to pneumatic actuators and pick-and-place units.

engineering

Packaging equipment

Supply lubricated air to case packers and palletizers, where the 225 cc oil bowl supports extended operation between refills.

Is the Airtac GAFC Air Service Unit GAFC50020LNW the Right Air-Prep Unit?

Choose the GAFC500 for a 3/4in port with a 7000 L/min flow envelope plotted at 0.7 MPa inlet, stepping up from the GAFC400's 6000 L/min curve. The L type caps regulation at 0.4 MPa, so if your machine may require more pressure, select the standard S version instead. The PC bowl is the default build, and the 5 um element filters finer than the standard 40 um grade, though it will need more frequent service. The semi-auto drain operates on pressure drops, with a manual override for on-demand draining, and the PT thread suits standard pipe fittings. Since no gauge is supplied, plan to add one at the 1/4in connection to monitor the setpoint. The filter-regulator and lubricator are orderable separately as GAFR500-20 and GAL500-20. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.

Quick checklist

  • ✓ Body size for your peak flow (3/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 108 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1910 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR500-20 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC50020LNW FAQ

This unit operates from 0.15 to 0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It works in temperatures from -5 to 70 C, uses ISO VG 32 oil, has a 108 cc drain bowl and a 225 cc oil bowl, and weighs 1910 g.

The N in the code after the port indicates no gauge is supplied. The GAFC500 body has a 1/4in gauge connection, so you can add a pressure gauge there if you need to read the set pressure directly.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC50020LNW

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC50020LNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.