The AirTAC Airtac GAFC Air Service Unit GAFC50020LNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size3/4"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialPC
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight1910 g
$113.61 $124.97Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC50020LNWK

This GAFC50020LNWK is a two-piece F.R.L. combination: a GA-series filter-regulator joined on a T bracket to a GA-series lubricator. The 3/4in port and 1910 g mass put it in the upper-middle size class, suited to a machine header feeding several actuators rather than a single small cylinder.

Air enters the first body where the 5 um element traps fine particles and the regulator sets pressure to 0.15-0.4 MPa (20-58 psi). The lubricator then adds a metered oil mist downstream, so oil never passes back through the regulator seat. The 108 cc condensate bowl and 225 cc oil bowl define the service interval; the lower-pressure type tops out at 0.4 MPa, so confirm the line never needs more.

Airtac GAFC Air Service Unit GAFC50020LNWK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC50020LNWK
SeriesGAFC500 F.R.L. combination
Port size3/4" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialPC
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl108 cc
Capacity of oil bowl225 cc
Recommended lubricantISO VG 32 or equivalent
Weight1910 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC500 is 1/4" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC50020LNWK

GAFC500GA500 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
20Port size 3/4". This body offers 20 = 3/4".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/4" gauge connection.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR500-20 filter & regulator, GAL500-20 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC500 · 3/4" · curve to 7000 L/min
One size downGAFC400
One size upGAFC600 (curve to 12000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC50020LNWK Is Used

factory

Machine Tool Header

Feed a 3/4in header on a CNC lathe or milling machine where multiple cylinders and clamps need filtered, regulated air at a stable low pressure.

precision_manufacturing

Assembly Line Lubrication

Supply oil-misted air to a multi-station assembly line with pneumatic screwdrivers or riveters that require consistent lubrication for tool life.

engineering

Low-Pressure Test Rig

Power a test fixture that cycles valves or actuators at pressures up to 0.4 MPa, where the 5 um filter protects sensitive instrumentation from particle contamination.

Is the Airtac GAFC Air Service Unit GAFC50020LNWK the Right Air-Prep Unit?

The L type regulates 0.15-0.4 MPa (20-58 psi), a deliberate choice for low-pressure circuits; if the machine may ever need more than 0.4 MPa, this is the wrong part. The 5 um element traps finer particles than the standard 40 um, at the cost of more frequent element service. No gauge is supplied, so the set pressure cannot be read without adding one to the 1/4in gauge connection. The semi-auto drain dumps condensate on each pressure drop, with a manual drain for on-demand use; the PC bowl is the standard build, and the reverse-flow (reflux) valve is fitted. Spares are orderable as GAFR500-20 and GAL500-20. With a 1.0 MPa max supply, there is about 0.6 MPa of headroom above the 0.4 MPa top of this unit's regulated range.

Quick checklist

  • ✓ Body size for your peak flow (3/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 108 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1910 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR500-20 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC50020LNWK FAQ

This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. The drain bowl holds 108 cc and the oil bowl 225 cc, with a total weight of 1910 g.

The N after the port code means no gauge is supplied; the 1/4in gauge connection is there if you add one later. The K code indicates a reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue. The L code sets the lower pressure range of 0.15-0.4 MPa.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC50020LNWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC50020LNWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.