The AirTAC Airtac GAFC Air Service Unit GAFC500C20ALK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC500C20ALK is a two-piece F.R.L. combination built for a 3/4in line. The first body houses the filter and regulator together, so air is cleaned and set to pressure before it moves on; the second body is the lubricator, which adds a controlled oil mist last. The metal bowl and automatic drain suit a fixed installation where condensate must clear itself without an operator.
The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), with a 40 um element and a circular gauge reading MPa/psi. The 108 cc condensate bowl and 225 cc oil bowl give this 1910 g unit a long service interval, and the reverse-flow valve is fitted. With a max supply of 1.0 MPa (145 psi), there is about 0.6 MPa of headroom above the top of the regulated band.
| Model | Airtac GAFC Air Service Unit GAFC500C20ALK |
|---|---|
| Series | GAFC500 F.R.L. combination |
| Port size | 3/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Capacity of oil bowl | 225 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1910 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC500 | GA500 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR500-20 filter & regulator, GAL500-20 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC500 · 3/4" · curve to 7000 L/min |
|---|---|
| One size down | GAFC400 |
| One size up | GAFC600 (curve to 12000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 3/4in header supplying a multi-spindle drilling machine, where the lower pressure protects fine feed units and the automatic drain clears wet shop air.
Run a pallet transfer conveyor with air cylinders that need consistent 0.3 MPa actuation, while the 225 cc oil bowl keeps lubricant available for a full shift.
Provide filtered, regulated air to a valve test rig where the 0.15-0.4 MPa band matches the test procedure and the metal bowl handles a warm environment.
Choose the GAFC500 for a 3/4in main line where the lower-pressure range is acceptable. The metal bowl is specified by the C code, and the automatic drain by the A code; the K code adds the reverse-flow valve. The 40 um element is standard, and the PT thread carries a gauge scaled in MPa/psi. If the machine may ever need more than 0.4 MPa, step to a standard-type unit instead. The filter-regulator and lubricator are orderable separately as GAFR500-20 and GAL500-20. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR500-20 filter-regulator on that branch instead of the full combination.
The working pressure range is 0.15-0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C. The condensate bowl holds 108 cc and the oil bowl 225 cc. Recommended lubricant is ISO VG 32, and the unit weighs 1910 g.
The K code specifies a reverse-flow (reflux) valve fitted to the unit. It is shown as a separate pneumatic symbol in the catalogue. The unit also has a metal bowl and an automatic drain, so it is ready for continuous operation without manual bowl draining.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.