The AirTAC Airtac GAFC Air Service Unit GAFC600C25ASK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This GAFC600C25ASK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a shared T-bracket with quick clamps. The 1in port and 3430 g mass put it at the top of the GAFC size range, built for high-flow machine headers rather than small actuator feeds.
Air enters the first body where the 40 um element strips solids and moisture, and the regulator sets pressure to 0.15-0.9 MPa (20-130 psi). The lubricator then adds a metered oil mist downstream, so oil never passes back through the regulator seat. The metal bowl holds 205 cc of condensate and the oil bowl 410 cc, with an automatic drain clearing water without an operator.
| Model | Airtac GAFC Air Service Unit GAFC600C25ASK |
|---|---|
| Series | GAFC600 F.R.L. combination |
| Port size | 1" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 205 cc |
| Capacity of oil bowl | 410 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 3430 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC600 | GA600 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: Metal (C) only. |
| 25 | Port size 1". This body offers 20 = 3/4", 25 = 1". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) only. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR600-25 filter & regulator, GAL600-25 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC600 · 1" · curve to 12000 L/min |
|---|---|
| One size down | GAFC500 |
| Build order | Filter & regulator → bracket → lubricator |
Feed a multi-spindle machining center's pneumatic clamping and tool-change system with the 1in port and 410 cc oil bowl, keeping lubrication consistent across several actuators.
Supply a bank of cylinder-driven pushers and film-seal bars on a packaging line, where the automatic drain and large 205 cc condensate bowl reduce maintenance stops.
Run a network of pneumatic screwdrivers and pick-and-place units on an assembly station, relying on the 40 um element to protect precision valves and the regulator to hold set pressure.
Choose the GAFC600 when your line needs the full 1in port and the 12000 L/min flow envelope plotted at 0.7 MPa inlet. The metal bowl is specified by the C code, and the automatic drain (A) suits unattended operation. A circular gauge is fitted, reading MPa/psi on the PT thread, and the reverse-flow (reflux) valve is included per the K code. The 40 um element is standard; step to the 5 um W option only if you accept more frequent element service. Spares are the GAFR600-25 filter-regulator and GAL600-25 lubricator, both orderable separately. If the line must stay oil-free, omit the lubricator and choose a plain GAFR filter-regulator instead. With a 1.0 MPa max supply, you have about 0.1 MPa of headroom above the 0.9 MPa top of the regulated range, so plan your inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR600-25 filter-regulator on that branch instead of the full combination.
The working pressure range is 0.15-0.9 MPa (20-130 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C and uses ISO VG 32 lubricant. The drain bowl holds 205 cc, the oil bowl 410 cc, and the unit weighs 3430 g.
The A code specifies an automatic drain that clears condensate from the 205 cc metal bowl without operator action. This is ideal for lines that run continuously or in locations where manual draining would be overlooked, keeping the filter element from sitting in water.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.