The AirTAC GAFR Adjustable Filter Regulator GAFR20008LJNTK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR20008LJNTK is a compact filter & regulator from AirTAC, combining a diversion filter and a balanced pressure regulator in a single body. This 1/4in unit handles a lower pressure range of 0.15-0.4 MPa (20-58 psi) and comes with a 40 um element, making it a space-saving choice for light-duty circuits.
With no gauge fitted, the 1/8in gauge connection is ready for a field-installed unit. The 25 cc condensate bowl and 290 g weight define its small footprint, while the built-in reverse-flow (reflux) valve is included as an ordering difference. This model ships without a mounting bracket, so plan for panel mounting or an existing support structure. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR20008LJNTK |
|---|---|
| Series | GAFR200 filter & regulator |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Bracket | Not included (J) |
| Weight | 290 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR200 is 1/8" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR200 | GA200 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC200-08 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR200 · 1/4" · curve to 2000 L/min |
|---|---|
| One size up | GAFR300 (curve to 3500 L/min) |
| Add a lubricator | GAFC200-08 (F.R.L. combination) |
Feed a single pneumatic clamp or fixture on a benchtop assembly station. The 1/4in port and 290 g weight suit compact frames, while the lower pressure range protects delicate workpieces.
Power a small cylinder on a pick-and-place arm or a parts feeder. The 40 um element keeps particulates away from the actuator seals, and the 25 cc bowl is easy to check during shift changes.
Provide a stable, low-pressure air source for a lab fixture or calibration rig. The balanced regulator holds the setpoint as shop pressure fluctuates, and the no-gauge version lets you add your own precision readout.
Choose this GAFR200 body for small jigs or single actuators where 1/4in ports and a 290 g mass fit tight layouts. The lower-pressure L type tops out at 0.4 MPa, so confirm your circuit never needs more than that; the semi-auto+manual drain requires periodic attention, and the PC bowl suits standard shop conditions. The missing bracket (J) and missing gauge (N) are deliberate omissions for panel-mount or remote-read applications, while the 40 um element handles general filtration. The reflux valve (K) is fitted as specified, and the NPT thread matches common local fittings. If lubrication is needed downstream, order the matching GAFC200-08 combination instead. With a 1.0 MPa max supply, this unit leaves about 0.6 MPa above the 0.4 MPa top of its regulated range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC200-08 combination; do not expect an oil mist from this unit.
The GAFR20008LJNTK is a filter & regulator with a 1/4in port, working pressure range of 0.15-0.4 MPa (20-58 psi), max pressure of 1.0 MPa (145 psi), and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, has a 25 cc drain bowl, and weighs 290 g. The unit comes with a 40 um element and a semi-auto plus manual drain.
The N code after the port means no gauge is supplied, leaving a 1/8in gauge connection for a field-installed unit. The J code means no mounting bracket is included, so you need a panel mount or an existing bracket. This configuration is for installations where the operator reads pressure from a remote or line gauge and where space is too tight for a standard bracket.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.