The AirTAC GAFR Adjustable Filter Regulator GAFR200C08ASJNWTK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR200C08ASJNWTK is a filter & regulator that combines air filtration and pressure regulation in a single metal-bodied unit. It handles a 1/4in port and delivers a regulated output from 0.15 to 0.9 MPa (20-130 psi) while trapping water and solids with its 5 um element.
This compact 290 g unit spins incoming air to separate liquid water and solid particles into its 25 cc condensate bowl. The balanced regulator holds the set pressure steady as supply varies, and the self-locking knob resists drift from vibration, making it a stable choice for space-constrained machine builds. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR200C08ASJNWTK |
|---|---|
| Series | GAFR200 filter & regulator |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Bracket | Not included (J) |
| Weight | 290 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR200 is 1/8" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR200 | GA200 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC200-08 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR200 · 1/4" · curve to 2000 L/min |
|---|---|
| One size up | GAFR300 (curve to 3500 L/min) |
| Add a lubricator | GAFC200-08 (F.R.L. combination) |
Feed a single precision pneumatic valve or small actuator on a benchtop assembly station, where the 5 um element protects sensitive internals from fine particulate.
Mount this 290 g unit directly to a panel in a tight control cabinet, using the omitted bracket (J) to save rail space while supplying clean, regulated air to a small cylinder.
Use the automatic drain on a humid production line to continuously purge condensate from the 25 cc bowl, protecting downstream tooling from water carryover.
Choose the GAFR200 body for light-duty circuits with 1/4in ports, where its 2000 L/min flow envelope at 0.7 MPa inlet provides ample capacity for a single actuator or small jig. The metal bowl suits demanding environments, while the automatic drain handles wet lines without manual intervention. This model omits the mounting bracket (J) for panel-mount installations and has no gauge (N), so plan to add one via the 1/8in gauge connection if you need to read outlet pressure. The 5 um element traps finer particles than the standard 40 um, and the fitted reverse-flow valve is an ordering difference to note. For lines needing lubrication downstream, order the matching GAFC200-08 combination instead. With a 1.0 MPa max supply, you have about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan your inlet pressure accordingly.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC200-08 combination; do not expect an oil mist from this unit.
Working pressure range is 0.15-0.9 MPa (20-130 psi), max pressure is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), temperature range is -5 to 70 C. The drain bowl holds 25 cc, the unit weighs 290 g, and it has a 1/4in port with a 5 um filter element.
The N code after the port means no gauge is supplied, leaving a 1/8in gauge connection for adding one later. The J code omits the mounting bracket, which suits panel-mount installations or existing bracket setups where the included bracket would be redundant.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.