The AirTAC GAFR Adjustable Filter Regulator GAFR200C08ASJWTK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR200C08ASJWTK is a filter and pressure regulator combined in a single body, saving rail space and reducing potential leak points compared to separate units. It handles 1/4in ports, delivers 0.15-0.9 MPa (20-130 psi), and uses a 5 um element to trap fine particles.
This version has a metal bowl and an automatic drain, so it suits lines where condensate builds quickly. The circular gauge with MPa/psi scale is fitted, and the pressed-in self-locking knob holds the set pressure steady against vibration. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR200C08ASJWTK |
|---|---|
| Series | GAFR200 filter & regulator |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Bracket | Not included (J) |
| Weight | 290 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR200 | GA200 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC200-08 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR200 · 1/4" · curve to 2000 L/min |
|---|---|
| One size up | GAFR300 (curve to 3500 L/min) |
| Add a lubricator | GAFC200-08 (F.R.L. combination) |
Feed a small pneumatic valve or instrument air circuit where the 5 um element protects fine internals from particle wear.
Supply a single test fixture or calibration setup with stable pressure, using the automatic drain for unattended operation.
Mount directly on a small assembly machine frame where the 290 g weight and 1/4in port fit tight layouts without tubing support.
Choose this GAFR200 for small jigs or single actuators needing clean, regulated air at 1/4in ports. The metal bowl (C) is a build choice; the 5 um element (W) filters finer than the standard 40 um, ideal for precision valves but requiring more frequent service. The automatic drain (A) removes condensate without manual attention, and the reverse-flow valve (K) is fitted as an ordering difference. No bracket (J) is included, so plan for panel mounting or an existing bracket. The NPT thread means the gauge reads MPa/psi. With a 1.0 MPa max supply, you have about 0.1 MPa above the 0.9 MPa top of the regulated range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC200-08 combination; do not expect an oil mist from this unit.
Working pressure is 0.15-0.9 MPa (20-130 psi), max pressure is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), temperature range is -5 to 70 C. The drain bowl holds 25 cc and the unit weighs 290 g. It uses a 5 um element and has an automatic drain.
The metal bowl (C) is a material choice for the condensate chamber; the automatic drain (A) handles water removal. The J code means the mounting bracket is omitted, so you need a panel mount or existing bracket. The reverse-flow valve (K) is fitted as an ordering difference.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.