The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR600C20ASJK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR600C20ASJK is a filter & regulator that combines a diversion filter and a balanced pressure regulator in a single metal body, eliminating the need for a separate filter and regulator pair. It handles 3/4in ports, operates from 0.15-0.9 MPa (20-130 psi), and uses a 40 um element to remove water and solid particles from the air stream.
This 1880 g unit is the largest in the GAFR series, with a 205 cc condensate bowl and an automatic drain for unattended operation. The pressed-in self-locking knob resists set-pressure drift from vibration, while the circular gauge with clip and magnifier saves panel space.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR600C20ASJK |
|---|---|
| Series | GAFR600 filter & regulator |
| Port size | 3/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 205 cc |
| Bracket | Not included (J) |
| Weight | 1880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR600 | GA600 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: Metal (C) only. |
| 20 | Port size 3/4". This body offers 20 = 3/4", 25 = 1". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) only. |
| J | No bracket (J) — supplied without the mounting bracket. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC600-20 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR600 · 3/4" · curve to 12000 L/min |
|---|---|
| One size down | GAFR500 |
| Add a lubricator | GAFC600-20 (F.R.L. combination) |
Feed a central header for a multi-station assembly machine where several actuators and valves draw air simultaneously, relying on the 12000 L/min plotted envelope at 0.7 MPa inlet.
Set a stable 0.6 MPa (87 psi) for a long conveyor system with multiple pneumatic cylinders, using the balanced regulator to hold pressure as line demand fluctuates.
Supply a large press or forming station that needs consistent air pressure and clean air, with the 40 um element protecting downstream precision valves.
The GAFR600 is the top size class, with a 3/4in port and a flow curve plotted to 12000 L/min at 0.7 MPa inlet, making it suitable for machine headers or multi-station lines. The metal bowl is the only option for this body, and the automatic drain (A) handles condensate without manual intervention. The J code means no mounting bracket is included, so plan for a panel mount or existing bracket. The K code indicates a reverse-flow (reflux) valve is fitted; the gauge reads in MPa/psi with PT threads. If your line needs lubrication downstream, order the matching GAFC600-20 combination instead. 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC600-20 combination; do not expect an oil mist from this unit.
Working pressure range is 0.15-0.9 MPa (20-130 psi), max pressure is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), temperature range is -5 to 70 C, drain bowl capacity is 205 cc, and weight is 1880 g.
The K code indicates a reverse-flow (reflux) valve is attached to the unit. It is an ordering difference from the standard model; the catalogue defers its function to a separate page not included in our data.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.