verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-10 FRL Unit (GC30010AC1WT)

The AirTAC GC300-10 FRL Unit (GC30010AC1WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$121.11 $128.61Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-10 drain, gauge and thread option on one page All GC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-10 FRL Unit (GC30010AC1WT)

The GC30010AC1WT is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator for compressed air. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The W code fits the finer 5 um filter element instead of the standard 40 um, giving cleaner air for sensitive downstream equipment, while the automatic drain on the filter bowl expels condensate without manual attention. The regulator covers 0.15-0.9 MPa (20-130 psi) in this automatic-drain configuration, and the C1 code adds an external round gauge with an MPa scale.

This is a genuine AirTAC part from the G series, which spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch. Drain types, gauges and G/BSPP or NPT threads are available as orderable options. Flow is published as curves rather than a single rated figure, so we confirm sizing and datasheet figures on request.

AirTAC GC300-10 FRL Unit (GC30010AC1WT) Technical Specifications

ModelAirTAC GC300-10 FRL Unit (GC30010AC1WT)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-10 FRL Unit (GC30010AC1WT)

GC300G-series F.R.L. combination, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT3/8" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-10 FRL Unit (GC30010AC1WT) Is Used

science

Laboratory pneumatic circuits

Finely filtered, regulated and lubricated air to benchtop test rigs and lab actuation, where the 5 um element protects sensitive pneumatic components from particulates.

precision_manufacturing

Optical lens production cell

Air preparation for handling and clamping actuators in a lens-finishing cell, with 5 um filtration helping keep contamination away from precision work.

air

Textile machine air supply

A point-of-use F.R.L. set on a weaving or spinning machine air line, where the automatic drain manages condensate and the lubricator serves the machine's air cylinders.

Is the AirTAC GC300-10 FRL Unit (GC30010AC1WT) the Right Station?

Specify the W (5 um) grade when downstream instruments, valves or processes need finer filtration than the standard 40 um; the trade is a somewhat higher duty on the element. Size 300 with the 3/8 inch NPT port serves mid-range demand - step to size 400/600 for more flow or size 200 for less. The automatic drain (A) suits unattended operation; manual and differential-pressure drains are also in the series. The round MPa gauge in this code can be swapped for a square gauge or a psi/bar scale.

This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Bracket mounting is available. Because flow appears only as published curves rather than a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.

AirTAC GC300-10 FRL Unit (GC30010AC1WT) FAQ

Flow for this unit is published by AirTAC as performance curves rather than a single rated figure, so no single number is quoted here. Tell us your pressure and air demand and we will confirm the sizing from the datasheet on request.

The W fits a 5 um filter element instead of the standard 40 um, for finer filtration. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-10 FRL Unit (GC30010AC1WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30010AC1WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.