AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-10 FRL Unit (GC30010AC1WTK)

The AirTAC GC300-10 FRL Unit (GC30010AC1WTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$136.04 $143.54Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-10 drain, gauge and thread option on one page All GC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-10 FRL Unit (GC30010AC1WTK)

The GC30010AC1WTK is an AirTAC GC-series three-unit F.R.L. combination - separate filter, regulator and lubricator - with a 5 um filter element (W) and a reverse (check) valve fitted (K). This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The filter bowl has an automatic drain, the regulator covers 0.15-0.9 MPa (20-130 psi) in this automatic-drain configuration, and the C1 code adds an external round gauge with an MPa scale.

This is a genuine AirTAC part from the G series, available in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch. Alternative drains, the standard 40 um grade, square gauges and psi/bar scales, and G/BSPP or NPT threads are all catalogue options. Flow is published as curves rather than a single rated figure, so we confirm sizing and datasheet figures on request.

AirTAC GC300-10 FRL Unit (GC30010AC1WTK) Technical Specifications

ModelAirTAC GC300-10 FRL Unit (GC30010AC1WTK)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-10 FRL Unit (GC30010AC1WTK)

GC300G-series F.R.L. combination, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT3/8" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-10 FRL Unit (GC30010AC1WTK) Is Used

valve

Process control valve actuation

Clean, regulated and lubricated air to pneumatic valve positioners and actuators on a process skid, with the 5 um element protecting sensitive pilot components.

factory

Food packaging machinery supply

Air preparation for form-fill-seal packaging machines, where finer filtration supports hygiene-sensitive equipment and the check valve helps hold circuit pressure.

build

Spray boothAtomizer air feed

Filtered and pressure-stabilised air to spraying and atomising equipment in a finishing line, read and set via the MPa gauge and served continuously by the automatic drain.

Is the AirTAC GC300-10 FRL Unit (GC30010AC1WTK) the Right Station?

Pick this code when you need both finer 5 um filtration and a reverse (check) valve in the three-unit set - for instance where clean air must be held downstream if the supply line drops. Size 300 with the 3/8 inch NPT port covers mid-range demand; adjust the size step (200 to 600) to match required flow. The automatic drain (A) keeps maintenance low; manual and differential-pressure drains are offered elsewhere in the series.

The round MPa-scale gauge can be replaced by a square gauge or a psi/bar scale when ordering. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published only as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.

AirTAC GC300-10 FRL Unit (GC30010AC1WTK) FAQ

Yes - on request. AirTAC publishes flow as performance curves rather than a single rated figure, so we do not state one number here. Send your working pressure and consumption and we will confirm the datasheet figures and correct sizing.

WK combines two options: a 5 um filter element (finer than the standard 40 um) and a fitted reverse (check) valve. The base decode stays the same - size 300, NPT3/8 port, NPT thread, automatic drain and a round MPa-scale gauge - so it suits circuits needing both cleaner air and downstream pressure retention.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-10 FRL Unit (GC30010AC1WTK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30010AC1WTK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.