AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-10 FRL Unit (GC30010AC2T)

The AirTAC GC300-10 FRL Unit (GC30010AC2T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$121.11 $128.61Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-10 drain, gauge and thread option on one page All GC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-10 FRL Unit (GC30010AC2T)

The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator that together clean, regulate and oil-mist lubricate a compressed-air line. This GC30010AC2T is built in size 300 with 3/8 in NPT ports, so it suits a mid-size supply main feeding several downstream valves and cylinders. The filter element is the standard 40 um grade, the bowls drain automatically, and the regulator carries an external round gauge with a psi scale for easy setpoint reading. Maximum working pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part from the G-series air-treatment range, which spans sizes 200, 300, 400 and 600 with a choice of ports, drain types, filter grades and gauge scales. On the size 300 unit the filter and lubricator bowls are PC (polycarbonate). Rated flow for this series is published as curves rather than a single figure, so ask us and we will confirm the datasheet and sizing figures for your application on request.

AirTAC GC300-10 FRL Unit (GC30010AC2T) Technical Specifications

ModelAirTAC GC300-10 FRL Unit (GC30010AC2T)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-10 FRL Unit (GC30010AC2T)

GC300G-series F.R.L. combination, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT3/8" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-10 FRL Unit (GC30010AC2T) Is Used

precision_manufacturing

CNC machine tool air supply

A filtered, regulated and lubricated 3/8 in feed ahead of a machining centre's pneumatic tool-clamp and chip-clearing circuits, keeping spindle-drawbar cylinders supplied with clean, correctly pressured and oiled air.

factory

Packaging line drop

A point-of-use F.R.L. on a carton-sealing or shrink-wrap line, feeding sealing jaws and case-eject cylinders with water-free air, a stable pressure setpoint and a fine oil mist for long seal-cylinder life.

conveyor_belt

Conveyor gate cylinders

Conditioning the air for diverter-gate and stopper cylinders on a parcel-sort conveyor, where automatic drain bowls handle condensate through multi-shift operation without daily manual draining.

Is the AirTAC GC300-10 FRL Unit (GC30010AC2T) the Right Station?

Size 300 with 3/8 in NPT ports is the middle step of the GC range; if your line demand sits near the top of a 300's flow curve, step up to size 400 for more headroom, or down to size 200 for compact branch lines. Drain choice: this code has automatic drain (A), which empties the filter bowl without operator attention; manual-drain and differential-pressure variants are available if you prefer scheduled draining. Filter grade is the standard 40 um element; specify W codes for the 5 um option where finer particulate protection is needed. The gauge here is the external round type on a psi scale; MPa and bar scales are offered. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow in this series is published as curves, not a single rating, so send us your line conditions and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.

AirTAC GC300-10 FRL Unit (GC30010AC2T) FAQ

AirTAC publishes G-series flow performance as curves rather than a single rated-flow figure, so we do not quote one number. Tell us your line pressure and air demand and we will confirm the correct size and the datasheet flow figures for the GC30010AC2T on request before you order.

The A in this code means both drain-relevant bowls empty themselves as condensate collects, which suits units mounted in awkward positions or on lines running unattended shifts. Manual-drain versions cost less but need an operator to open the drain, and differential-pressure variants drain on a pressure-differential signal. Pick automatic where drainage visits are impractical.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-10 FRL Unit (GC30010AC2T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30010AC2T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.