AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-10 FRL Unit (GC30010F1T)

The AirTAC GC300-10 FRL Unit (GC30010F1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$107.41 $114.91Save 6% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-10 drain, gauge and thread option on one page All GC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-10 FRL Unit (GC30010F1T)

The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator built as one set, so the air reaching your cylinders, valves and tools is filtered, held at a set pressure and oil-mist lubricated. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The F1 gauge option keeps the regulator's embedded square gauge with an MPa scale. Maximum inlet pressure is 1.0 MPa (145 psi), the regulator adjusting range with the differential-pressure drain is 0.15-0.9 MPa (20-130 psi), and operating temperature is -5 to 70 C, non-freezing. On size 300, the filter and lubricator bowls are PC (polycarbonate).

This is a genuine AirTAC part. The GC series covers sizes 200, 300, 400 and 600 with matching ports, and the same combination is orderable with a 5 um element (W), automatic or manual drain, an external round gauge or psi and bar scales, a reverse check valve (K), or G (BSPP) and NPT threads instead of the NPT standard. Flow is published as curves rather than a single rating, so ask us to confirm datasheet figures and sizing on request.

AirTAC GC300-10 FRL Unit (GC30010F1T) Technical Specifications

ModelAirTAC GC300-10 FRL Unit (GC30010F1T)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-10 FRL Unit (GC30010F1T)

GC300G-series F.R.L. combination, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT3/8" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-10 FRL Unit (GC30010F1T) Is Used

factory

Weaving loom air supply

Conditions the air feeding loom valve blocks and shed-forming cylinders in a weaving shed, keeping particulate out and a steady regulated, lubricated supply through continuous production.

build

Pneumatic clamping fixtures

Serves the clamp-and-uncclamp cylinders on machining and welding fixtures, where the regulator holds the clamping pressure and the lubricator mists the cylinder seals cycle after cycle.

valve

Actuated process valves

Feeds quarter-turn pneumatic actuators on plant valves, providing filtered, regulated and lubricated air so the positioner and actuator seals see clean, conditioned supply air.

Is the AirTAC GC300-10 FRL Unit (GC30010F1T) the Right Station?

F1 selects the regulator's embedded square gauge on an MPa scale, which keeps the panel footprint tight; an external round gauge or psi/bar scales are the alternative codes. Size 300 with 3/8 in. ports suits mid-range branch lines; step to 200/400/600 as your flow requires. The 40 um element is the standard grade, with 5 um (W) for finer duties, and the differential-pressure drain is the default, with automatic and manual drain codes available. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Since GC flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.

AirTAC GC300-10 FRL Unit (GC30010F1T) FAQ

Flow for the GC series is published by AirTAC as performance curves rather than a single rated figure, so we do not state a number. Share your required flow and working pressure and we will confirm the size from the datasheet on request.

F1 specifies the regulator's embedded square pressure gauge with an MPa scale. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-10 FRL Unit (GC30010F1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30010F1T and will confirm price, availability and lead time — usually within 7 hours.