The AirTAC GC300-10 FRL Unit (GC30010MC2TK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$122.34 $129.84Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-10 drain, gauge and thread option on one page All GC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-10 FRL Unit (GC30010MC2TK)

The AirTAC GC300-10 is a three-piece F.R.L. combination that filters, regulates and lubricates compressed air from a single assembled set: a separate filter, a pressure regulator and an oil-mist lubricator. This size 300 unit is fitted with a 3/8 in NPT port, the standard 40 um filter element for general-purpose water and particulate removal, and a manual drain on the filter bowl, so condensate is released when an operator opens the drain rather than automatically. The regulator is the standard type with an adjustment range of 0.05-0.9 MPa (7-130 psi), and this configuration carries a round pressure gauge reading in psi, a reverse/check valve, and a mounting bracket.

This is a genuine AirTAC part. The GC combination is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and options include automatic or differential-pressure drains, a 5 um filter element (code W), square or round gauges with MPa, psi or bar scales, and G (BSPP) or NPT threads in place of the NPT standard. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application on request. Order code GC30010MC2TK has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC300-10 FRL Unit (GC30010MC2TK) Technical Specifications

ModelAirTAC GC300-10 FRL Unit (GC30010MC2TK)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-10 FRL Unit (GC30010MC2TK)

GC300G-series F.R.L. combination, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT3/8" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-10 FRL Unit (GC30010MC2TK) Is Used

factory

Automotive paint shop air supply

Feeds filtered, regulated and lubricated air to spray booths and air-driven paint equipment on an automotive refinishing line, where the 40 um element removes water and pipe scale and the lubricator mists oil to downstream air tools.

precision_manufacturing

CNC machining cell tool supply

Conditions the air feeding clamps, air chucks and pneumatic tool circuits on a CNC machining cell, with the regulator holding a steady set pressure and the check valve holding downstream pressure if the main supply drops.

conveyor_belt

Packaging line actuator supply

Supplies treated air to cylinders and air cylinders driving cartoners, case packers and conveyor diverters on a packaging line, where the manual drain suits a shift-based maintenance routine and the psi gauge lets operators verify set pressure at a glance.

Is the AirTAC GC300-10 FRL Unit (GC30010MC2TK) the Right Station?

Start with the size and port: this GC300-10 is the size 300 frame with a 3/8 in NPT port, one step up from the 1/4 in size 200 units, so step up to size 400 or 600 if your line demands more flow - we can confirm the flow curves against your demand before you order. Drain choice matters in practice: this unit has a manual drain, which suits attended installations, while automatic (code A) or differential-pressure (default) drains suit unattended duty. The 40 um element is the standard grade; specify 5 um (code W) for finer protection. The gauge here is round with a psi scale; square gauges and MPa or bar scales are alternatives. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.

AirTAC GC300-10 FRL Unit (GC30010MC2TK) FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a rated l/min or SCFM number. Send us your operating pressure and air demand and we will confirm the flow from the datasheet curves for this size 300, 3/8 in unit on request.

The M in the code GC30010MC2TK specifies a manual drain on the filter bowl: condensate is released when an operator opens the drain, which suits attended installations with a regular maintenance routine. If the unit will run unattended, the same size is available with an automatic drain (code A) or the differential-pressure drain that is the catalogue default - ask us to quote the variant you need.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-10 FRL Unit (GC30010MC2TK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30010MC2TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.