The AirTAC GC300-15 FRL Unit (GC30015LC1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series is a three-unit F.R.L. set - separate filter, regulator and lubricator - that conditions compressed air in one assembly. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
This is a genuine AirTAC part. The G series spans 200/300/400/600 sizes with a choice of drains, filter grades, gauge styles and G or NPT threads; max working pressure is 1.0 MPa (145 psi) and the temperature range is -5 to 70 C (non-freezing). The bowl on this 300 size is polycarbonate (PC). Because this is the low-pressure type, we confirm the exact adjustment envelope and all datasheet figures on request. Order code GC30015LC1T has NPT ports (the T in the code) for North American pipe fittings.
| Model | AirTAC GC300-15 FRL Unit (GC30015LC1T) |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · PT1/2" · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-15 |
| Build order | Filter → regulator → lubricator |
Conditions low-pressure compressed air feeding bench valves and glassware-drying stations in a lab service ring, read on the MPa gauge.
Regulates supply to low-pressure forming and ejection air circuits on a plastics thermoforming line, where full plant pressure is not wanted.
Feeds air tables and flotation pads that run at reduced pressure, with filtered, oil-misted air protecting the porous surfaces.
This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The L code selects the low-pressure regulator type; confirm the working pressure of your circuit with us before ordering. Choose the standard type if your line runs at full plant pressure.
The round MPa gauge sits external to the body, and the 40 um element is the standard filtration grade (5 um is available as W). Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.
AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote one number here. Share your application and we will confirm the datasheet flow data and the right size for your circuit on request.
The L code selects the low-pressure regulator type for circuits that run below standard plant pressure, and C1 specifies an external round gauge scaled in MPa. We confirm the exact adjustment range of the low-pressure type on request before you order.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.