The AirTAC GC300-15 FRL Unit (GC30015MF1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The GC30015MF1T is an AirTAC G-series three-unit F.R.L. combination bringing filter, regulator and lubricator together as one set. It removes water and 40 um particulate, regulates outlet pressure over 0.05-0.9 MPa (7-130 psi) with its manual drain, and meters oil mist to downstream equipment. This code specifies the embedded square gauge with an MPa scale, and the 1/2 in NPT ports; the 300-size bowls are PC (polycarbonate).
This is a genuine AirTAC part. The GC series also comes in 200, 300, 400 and 600 sizes with 1/8 in to 1 in ports, G (BSPP) or NPT threads, automatic or differential-pressure drains, a 5 um element (W suffix) and bar or psi gauge scales if MPa does not match your plant convention. Flow is published only as curves, so we confirm the datasheet and sizing for your application on request.
| Model | AirTAC GC300-15 FRL Unit (GC30015MF1T) |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · PT1/2" · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-15 |
| Build order | Filter → regulator → lubricator |
Conditions the air powering diverters, stops and gate cylinders along a distribution conveyor, keeping actuator speed consistent through regulated pressure on a shared header.
Filters, regulates and lubricates air for dock levellers, tail-lift test rigs and trailer brake test stands in a depot workshop, where manual bowl draining fits supervised shifts.
Feeds press-fit cylinders and screwdriver balancers at an assembly bench, adding controlled oil mist so tools and cylinders keep their internal lubrication over long production runs.
Size 300 with a 1/2 in NPT port is the middle step of the GC series; compare the 200, 400 and 600 steps against your line's flow demand. The manual drain (M) means bowls are emptied by hand - pick automatic or differential-pressure drain for unattended sites, noting the regulator range is 0.05-0.9 MPa with manual drain versus 0.15-0.9 MPa otherwise. The square embedded gauge here reads in MPa; round gauges and bar or psi scales are orderable. The standard 40 um element covers general plant air, with the 5 um W suffix for finer duty. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G (BSPP) and NPT are order options.
Because flow appears only as curves rather than a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.
There is no single published rated flow for the GC series - AirTAC presents flow as curves. We confirm the datasheet and the right size for your duty on request; share your working pressure and air demand and we will check the GC30015MF1T against them before you order.
The F1 code here gives the square embedded gauge with an MPa scale, which suits panels built around metric pressure units. If your technicians work in bar or psi, order the equivalent code with scale 3 (bar) or 2 (psi), or choose a round external gauge where the panel design calls for one. Function and plumbing are otherwise identical.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.