The AirTAC GC300-15 FRL Unit (GC30015MF1TK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The GC30015MF1TK is an AirTAC G-series three-unit F.R.L. combination with the K suffix, which fits a reverse (check) valve so downstream pressure is retained if the supply side drops. As a set it removes water and 40 um particulate, regulates outlet pressure over 0.05-0.9 MPa (7-130 psi) with its manual drain, and meters oil mist downstream. The square embedded gauge reads in MPa, the 300-size bowls are PC (polycarbonate), and the ports are 1/2 in NPT.
This is a genuine AirTAC part. The same GC series is offered in 200, 300, 400 and 600 sizes with 1/8 in to 1 in ports, G (BSPP) or NPT threads, automatic or differential-pressure drains, a 5 um element (W) and bar or psi gauge scales. Flow is published only as curves, so we confirm the datasheet and sizing for your application on request.
| Model | AirTAC GC300-15 FRL Unit (GC30015MF1TK) |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · PT1/2" · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-15 |
| Build order | Filter → regulator → lubricator |
Feeds safety clamp and hold-down cylinders on a hydraulic-press cell, where the check valve helps retain the regulated charge in the clamp side if upstream supply is interrupted.
Conditions air for rotary indexing tables and their stopper cylinders, keeping the circuit charged through the check valve so position-holding actuators are not lost to supply dips.
Supplies a robot gripper station with filtered, regulated, lubricated air on a moving manifold, retaining gripper pressure via the reverse valve during brief supply transients.
Size 300 with a 1/2 in NPT port is the GC series' mid step - verify against 200/400/600 for your flow need. The K suffix is the deciding choice here: it holds pressure downstream of the set, useful where a supply drop must not dump a charged circuit; without it the plain GC30015MF1 applies. Manual drain (M) suits attended installs - automatic or differential-pressure drain covers unattended ones, with the regulator range 0.05-0.9 MPa versus 0.15-0.9 MPa respectively. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
Flow is published as curves rather than a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.
Yes - on request. AirTAC publishes flow for the GC series as curves rather than one rated figure, so instead of quoting a number we confirm the datasheet and check the size against your inlet pressure and air demand before you order.
The K suffix fits a reverse (check) valve in the unit, so downstream pressure is held if the supply side loses pressure - useful for clamp, gripper and holding circuits. Everything else is unchanged: same 1/2 in NPT ports, manual drain, 40 um element, square MPa gauge and 0.05-0.9 MPa regulator range.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.