verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-15 FRL Unit (GC30015MF2T)

The AirTAC GC300-15 FRL Unit (GC30015MF2T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$107.41 $114.91Save 6% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-15 FRL Unit (GC30015MF2T)

The GC30015MF2T is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one 300-size set on a NPT1/2 (1/2 in) port. This configuration carries the standard 40 um filter element with a manual drain on the filter bowl, a standard-type regulator with an embedded square gauge scaled in psi, and the lubricator for oil-mist delivery downstream. The polycarbonate bowls suit the -5 to 70 C (non-freezing) operating range, and the set is supplied with a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi), with a regulation range of 0.05-0.9 MPa (7-130 psi).

This is a genuine AirTAC part. The GC series is available in 200, 300, 400 and 600 sizes with a choice of ports, thread options (NPT on this code), manual, automatic or differential-pressure drains, 40 um or 5 um (W) filter grades, and gauge scale choices. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.

AirTAC GC300-15 FRL Unit (GC30015MF2T) Technical Specifications

ModelAirTAC GC300-15 FRL Unit (GC30015MF2T)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-15 FRL Unit (GC30015MF2T)

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-15 FRL Unit (GC30015MF2T) Is Used

factory

Automotive assembly plant air ring main

Feeding a 1/2 in distribution leg that serves assembly stations: the filter removes water and particulate, the regulator holds a steady working pressure, and the lubricator carries oil mist to air tools on the line.

precision_manufacturing

CNC machining cell with pneumatic clamping

Conditioning the supply to clamp cylinders and pallet-change actuators on a machining centre, where the regulator keeps clamping pressure consistent and the lubricator protects the valve and cylinder seals downstream.

conveyor_belt

Packaging line conveyor diverters and lifters

Supplying treated air to the diverter gates, pushers and lift cylinders on a bottling or carton conveyor, with the 40 um element keeping debris out of the directional valves and the psi gauge giving operators a local pressure readout.

Is the AirTAC GC300-15 FRL Unit (GC30015MF2T) the Right Station?

Start with the size and port: this unit is 300 size on NPT1/2, one step up from the 200 series, so choose it where your line needs the larger 1/2 in connection. Decide the drain type for the filter bowl - manual (as fitted here) means someone opens the drain periodically, while automatic and differential-pressure options drain without hands-on attention. The 40 um element is the standard grade; specify the W code if you need the 5 um option. The embedded square gauge is scaled in psi here, and MPa or bar scales are available. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G (BSPP) and NPT are order options, not delivery promises.

Because flow is published as curves rather than a single rated figure, we cannot quote one number here - ask us to confirm sizing against your application and the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

AirTAC GC300-15 FRL Unit (GC30015MF2T) FAQ

AirTAC publishes flow for this series as curves, not as a single rated number, so we do not quote a l/min, m3/h or SCFM figure. Tell us your application and we will confirm the flow data from the datasheet on request before you order.

The M in the code means the filter bowl has a manual drain: someone opens it periodically to release collected water. If you prefer hands-off draining, the same 300-size set is available with an automatic (A) or differential-pressure (blank) drain - note that the regulator adjustment range differs by drain type, with manual-drain versions covering 0.05-0.9 MPa (7-130 psi).

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-15 FRL Unit (GC30015MF2T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30015MF2T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.