The AirTAC GC300-15 FRL Unit (GC30015MLC1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
GC30015MLC1T is an AirTAC G-series three-unit F.R.L. combination for a 1/2 in. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. It carries a manual drain on the filter bowl, the standard 40 um filter element, and a round pressure gauge reading in MPa, with the lubricator adding an oil mist for downstream actuators and tools.
This is a genuine AirTAC part in the GC300 size. The G-series runs from size 200 to 600 with larger ports and higher flow, and the F.R.L. is offered with standard or low-pressure regulation, a choice of drain type, 40 or 5 um filtration, gauge shape and scale, three thread types (NPT on this code), and an optional bracket. Flow is published as curves rather than a single rating, so we confirm datasheet and sizing figures on request.
| Model | AirTAC GC300-15 FRL Unit (GC30015MLC1T) |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · PT1/2" · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-15 |
| Build order | Filter → regulator → lubricator |
Supplies conditioned, lubricated air to the sampling valves and small actuated dampers on a pilot process skid whose control loop holds the supply at a reduced pressure setting.
Feeds the nip rollers, web guides and idler tensioners on a paper converting line where the pneumatic circuits are run at gentle settings to avoid marking the web.
Prepares air for the light interlock gates and safety-flap cylinders around a press line, where the low-pressure type regulator keeps the actuation circuit at a modest setting.
Pick the L-type regulation when your circuit runs at a lower working pressure than a standard regulator setting targets; we will confirm the exact adjustment ceiling for the low-pressure version on request, while standard-type GC units with manual drain adjust 0.05-0.9 MPa (7-130 psi). GC300 with a 1/2 in. NPT port is the mid-large step of the range; GC200 and GC400/600 bracket it. The 40 um element is the standard general-air grade; the 5 um W option is there for sensitive valves. Manual drain suits attended sites; automatic and differential-pressure drains are available. The round external gauge reads in MPa here, with square gauges and bar or psi scales also offered. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G (BSPP) and NPT are orderable options. Flow is published only as curves, so ask us to confirm sizing before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.
Flow for the G-series is published as curves rather than a single rated figure, so we do not state a number here. Send us your air demand and we will confirm the datasheet curve and check the sizing against your application on request.
The L in the code selects the low-pressure regulator type, which has a lower maximum setting than the standard version - we confirm its exact range on request. The missing W keeps the standard 40 um element; add the W if you need 5 um filtration for sensitive valves.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.