verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-15 FRL Unit (GC30015MLC1T)

The AirTAC GC300-15 FRL Unit (GC30015MLC1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$107.41 $114.91Save 6% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-15 FRL Unit (GC30015MLC1T)

GC30015MLC1T is an AirTAC G-series three-unit F.R.L. combination for a 1/2 in. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. It carries a manual drain on the filter bowl, the standard 40 um filter element, and a round pressure gauge reading in MPa, with the lubricator adding an oil mist for downstream actuators and tools.

This is a genuine AirTAC part in the GC300 size. The G-series runs from size 200 to 600 with larger ports and higher flow, and the F.R.L. is offered with standard or low-pressure regulation, a choice of drain type, 40 or 5 um filtration, gauge shape and scale, three thread types (NPT on this code), and an optional bracket. Flow is published as curves rather than a single rating, so we confirm datasheet and sizing figures on request.

AirTAC GC300-15 FRL Unit (GC30015MLC1T) Technical Specifications

ModelAirTAC GC300-15 FRL Unit (GC30015MLC1T)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-15 FRL Unit (GC30015MLC1T)

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-15 FRL Unit (GC30015MLC1T) Is Used

science

Pilot-scale process skid actuation

Supplies conditioned, lubricated air to the sampling valves and small actuated dampers on a pilot process skid whose control loop holds the supply at a reduced pressure setting.

settings_input_component

Web converting line nip and idler controls

Feeds the nip rollers, web guides and idler tensioners on a paper converting line where the pneumatic circuits are run at gentle settings to avoid marking the web.

shield

Low-pressure guarding and interlock gates

Prepares air for the light interlock gates and safety-flap cylinders around a press line, where the low-pressure type regulator keeps the actuation circuit at a modest setting.

Is the AirTAC GC300-15 FRL Unit (GC30015MLC1T) the Right Station?

Pick the L-type regulation when your circuit runs at a lower working pressure than a standard regulator setting targets; we will confirm the exact adjustment ceiling for the low-pressure version on request, while standard-type GC units with manual drain adjust 0.05-0.9 MPa (7-130 psi). GC300 with a 1/2 in. NPT port is the mid-large step of the range; GC200 and GC400/600 bracket it. The 40 um element is the standard general-air grade; the 5 um W option is there for sensitive valves. Manual drain suits attended sites; automatic and differential-pressure drains are available. The round external gauge reads in MPa here, with square gauges and bar or psi scales also offered. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G (BSPP) and NPT are orderable options. Flow is published only as curves, so ask us to confirm sizing before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

AirTAC GC300-15 FRL Unit (GC30015MLC1T) FAQ

Flow for the G-series is published as curves rather than a single rated figure, so we do not state a number here. Send us your air demand and we will confirm the datasheet curve and check the sizing against your application on request.

The L in the code selects the low-pressure regulator type, which has a lower maximum setting than the standard version - we confirm its exact range on request. The missing W keeps the standard 40 um element; add the W if you need 5 um filtration for sensitive valves.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-15 FRL Unit (GC30015MLC1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30015MLC1T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.