verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-15 FRL Unit (GC30015MLF2TK)

The AirTAC GC300-15 FRL Unit (GC30015MLF2TK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$122.34 $129.84Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-15 FRL Unit (GC30015MLF2TK)

The GC30015MLF2TK is an AirTAC GC300 three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one 300-size unit with NPT1/2 (1/2 in) ports. The filter section removes water and particulate down to 40 um, the manual-drain bowl lets you discharge collected condensate by hand, and the lubricator meters oil mist into the air line to keep downstream air tools and actuators running smoothly. The regulator is the low-pressure type and carries a fitted square gauge reading in psi, and a reverse/check valve is fitted to hold the line against backflow.

This is a genuine AirTAC part. The GC family is available in 200, 300, 400 and 600 sizes with a choice of three thread types (NPT on this code), manual or automatic drain, a 5 um filter element (code W), gauge scale options and reverse/check valve. Max inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rating, so ask us to confirm sizing and datasheet figures against your application before ordering.

AirTAC GC300-15 FRL Unit (GC30015MLF2TK) Technical Specifications

ModelAirTAC GC300-15 FRL Unit (GC30015MLF2TK)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-15 FRL Unit (GC30015MLF2TK)

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-15 FRL Unit (GC30015MLF2TK) Is Used

factory

Assembly plant air ring main

Dropped off a 1/2 in NPT plant air main, the GC30015MLF2TK filters, regulates and lubricates the supply feeding a bay of impact wrenches and nutrunners, with the psi gauge giving operators a local pressure readout.

conveyor_belt

Packaging line actuator supply

On a carton-forming and sealing line, the unit conditions the air feeding cylinder-driven clamps and pushers, with the lubricator oil-misting the line so valve spools and cylinder seals run on lubricated air.

precision_manufacturing

Machine-tool pneumatic clamping

Feeding the clamping circuit of a CNC fixture setup, the combination removes water and 40 um-plus particulate, holds a steady low-pressure setpoint on the regulator, and the check valve helps hold the circuit against backflow.

Is the AirTAC GC300-15 FRL Unit (GC30015MLF2TK) the Right Station?

Step up or down through the 200 / 300 / 400 / 600 sizes to match the port and flow your line needs; this 300 unit sits at NPT1/2. Choose the drain to suit access: manual (this unit) for a supervised drain point, automatic for unattended condensate discharge, or differential-pressure as the default. The standard element is 40 um; specify 5 um (W) where finer particulate removal matters. Gauge scale is selectable (MPa, psi or bar) and this unit ships with the square gauge in psi; the reverse/check valve (K) is already fitted. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

One honest note on sizing: filter flow is published as curves, not a single rated figure, and the low-pressure regulator's adjustment range is not published in the data we hold. Ask us to confirm both against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

AirTAC GC300-15 FRL Unit (GC30015MLF2TK) FAQ

AirTAC publishes filter flow as curves rather than a single rated figure, so we do not quote one number here. Tell us your line pressure and the flow your application needs and we will confirm the sizing against the datasheet curves on request. The same applies to the low-pressure regulator's adjustment range, which is not published in the data we hold.

This unit has a manual drain: condensate collected in the filter bowl is discharged by hand, which suits supervised drain points. If the unit will sit unattended, order the automatic drain instead, or the differential-pressure drain as the default. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-15 FRL Unit (GC30015MLF2TK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30015MLF2TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.