The AirTAC GC400-10 FRL Unit (GC40010AC3TK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC40010AC3TK is a genuine AirTAC three-unit F.R.L. combination - separate filter, regulator and lubricator - with the K option fitted: a reverse (check) valve. In practice the set still filters compressed air to 40 um with an automatic-drain bowl, regulates downstream pressure between 0.15 and 0.9 MPa (20-130 psi) with the automatic drain, and meters oil mist, while the check valve guards against reverse flow through the unit. It carries a 3/8 in NPT port, a round external gauge reading in bar, and a maximum working pressure of 1.0 MPa (145 psi) from -5 to 70 C (non-freezing). Bowls on the 400 size are PC (polycarbonate).
This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Since flow appears only as curves in the AirTAC catalogue, we confirm flow and datasheet figures on request.
| Model | AirTAC GC400-10 FRL Unit (GC40010AC3TK) |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, bar scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT3/8" · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-10 |
| Build order | Filter → regulator → lubricator |
A machining cell running hydraulic-assist pneumatic fixture clamps uses this set at the branch supply: filtered 40 um air, regulated clamp pressure and lubricated air cylinders, with the check valve helping isolate the clamp circuit from upstream pressure decay when the main header vents.
In a laboratory automation island with pick-and-place mini grippers, this F.R.L. set conditions the 3/8 in NPT branch feeding the manifold. The automatic drain keeps condensate out of sensitive motion axes, and the bar-scale round gauge documents the set pressure for process records.
A water-treatment skid actuating butterfly valves with double-acting pneumatic actuators takes its instrument-grade supply through this set. Filtered, regulated, lubricated air feeds the positioner and actuator, and the reverse valve in the K variant supports the skid's anti-backflow arrangement.
This configuration suits a branch line where backflow protection matters: the K-suffix check valve is the only difference from the plain GC40010AC3. Keep the 400/3/8 in NPT port size if your demand sits within the range of a 3/8 in drop; go to size 600 for more flow. The automatic drain suits unattended duty; manual drain (M) fits supervised cells and widens the regulator range to 0.05-0.9 MPa (7-130 psi). The 40 um element is standard - order the W variant for 5 um. The bar-scale round gauge can be swapped for a square gauge on MPa, psi or bar scales.
Because published flow is curve data rather than one rated figure, ask us to confirm sizing for your line before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.
There is no single published rated flow for the GC400 series - AirTAC provides flow as curves. Rather than quote a figure we cannot back up, we will confirm the flow and datasheet data for your operating conditions on request; just send us your line pressure and demand.
K means a reverse (check) valve is fitted, so air cannot flow backwards through the set. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Choose the code without K if reverse flow is not a concern in your circuit.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.