The AirTAC GC400-10 FRL Unit (GC40010ALC1WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator working as one set. This GC40010ALC1WT is built on the 400 size with a 3/8 inch NPT port, carries the L low-pressure regulator type, and drains condensate from the filter bowl automatically. The W suffix fits the finer 5 um filter element, the MPa-scale round pressure gauge is specified, maximum inlet pressure is 1.0 MPa (145 psi), and the polycarbonate bowls on the filter and lubricator suit the non-freezing -5 to 70 C working range.
You are buying a genuine AirTAC part. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Rated flow is published as curves rather than a single figure, so ask us and we will confirm the datasheet and sizing for your line before you order.
| Model | AirTAC GC400-10 FRL Unit (GC40010ALC1WT) |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT3/8" · 5 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-10 |
| Build order | Filter → regulator → lubricator |
On a packaging line, this set conditions the 3/8 inch branch feeding gripper and clamp cylinders: water and fine 5 um filtration protect the valves, the automatic drain handles condensate without daily bleeding, the low-pressure regulator holds the gentle pressure delicate cartons need, and the lubricator mists oil to the seals.
Machining fixtures that hold thin-walled parts rely on swing clamps and edge clamps set at low regulated pressure to avoid distortion. This GC set filters the shop-air drop down to 5 um, regulates it in the low band via the L-type regulator and keeps oil mist moving to the clamp seals.
Laboratory and pilot-line rigs running diaphragm actuators and low-pressure load cylinders need clean, dry, lightly oiled air. This FRL on the rig supply line removes water and fine particles, drains itself automatically and lets the operator hold a low regulated set point.
Size 400 with a 3/8 inch port sits in the middle of the GC range; step down to 300 or up to 600 if your flow demand changes - and because flow is published as curves rather than one rated number, ask us to check the curves against your application before ordering. The automatic drain here suits unattended duty; manual-drain and differential-pressure versions are alternative order codes. This W version carries the 5 um element for finer protection of downstream valves and cylinders; drop the W for the standard 40 um grade. Gauge scale is MPa here; psi (2) and bar (3) scales are order options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote one number. Send us your line pressure, regulator setting and air consumption and we will confirm the sizing from the datasheet before you order.
The W suffix fits a 5 um filter element in place of the standard 40 um element, giving finer protection for precision valves, cylinders and gauges downstream. If your application only needs bulk water and particle removal, the non-W code with 40 um filtration is the usual choice.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.