verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-10 FRL Unit (GC40010ALF1T)

The AirTAC GC400-10 FRL Unit (GC40010ALF1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$168.92 $176.42Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-10 drain, gauge and thread option on one page All GC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC400-10 FRL Unit (GC40010ALF1T)

The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator working as one set. This GC40010ALF1T is built on the 400 size with a 3/8 inch NPT port, carries the L low-pressure regulator type, and drains condensate from the filter bowl automatically. Filtration is the standard 40 um element, the MPa-scale square gauge is specified, maximum inlet pressure is 1.0 MPa (145 psi), and the polycarbonate bowls on the filter and lubricator suit the non-freezing -5 to 70 C working range.

You are buying a genuine AirTAC part. The GC family spans the 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, and options include manual or differential-pressure drains, a 5 um filter element (suffix W), a round external gauge, psi or bar gauge scales, and G (BSPP) or NPT threads in place of the NPT standard. Rated flow is published as curves rather than a single figure, so ask us and we will confirm the datasheet and sizing for your line before you order.

AirTAC GC400-10 FRL Unit (GC40010ALF1T) Technical Specifications

ModelAirTAC GC400-10 FRL Unit (GC40010ALF1T)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-10 FRL Unit (GC40010ALF1T)

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-10 FRL Unit (GC40010ALF1T) Is Used

factory

Cartoning-line gripper air

On a packaging line, this set conditions the 3/8 inch branch feeding gripper and clamp cylinders: water and 40 um particulate are stripped out, the automatic drain handles condensate without daily bleeding, the low-pressure regulator holds the gentle pressure delicate cartons need, and the lubricator mists oil to the cylinder seals.

precision_manufacturing

Low-pressure clamping fixtures

Machining fixtures that hold thin-walled parts rely on swing clamps and edge clamps set at low regulated pressure to avoid distortion. This GC set filters the shop-air drop, regulates it in the low band via the L-type regulator and keeps oil mist moving to the clamp seals.

conveyor_belt

Conveyor diverter gates

Sorting and diverting gates on a conveyor run thousands of cycles per shift. Mounted on the drop line, this FRL keeps condensate out of the actuators via the automatic drain, lets the operator dial in low gate pressure, and feeds lubricant so cylinders keep smooth action.

Is the AirTAC GC400-10 FRL Unit (GC40010ALF1T) the Right Station?

Size 400 with a 3/8 inch port sits in the middle of the GC range; step down to 300 or up to 600 if your flow demand changes - and because flow is published as curves rather than one rated number, ask us to check the curves against your application before ordering. The automatic drain here suits unattended duty; manual-drain and differential-pressure versions are alternative order codes. The 40 um element is standard and the W suffix gives 5 um for finer protection. The F code here selects the MPa-scale square gauge; the C code gives an external round gauge, and psi (2) or bar (3) scales are order options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

AirTAC GC400-10 FRL Unit (GC40010ALF1T) FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote one number. Send us your line pressure, regulator setting and air consumption and we will confirm the sizing from the datasheet before you order.

Both read in MPa. F1 specifies the square gauge, while C1 specifies the optional external round gauge. Pick the style that matches the other AirTAC units already mounted on your panel; psi (code 2) and bar (code 3) scales are also available as order options.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC400-10 FRL Unit (GC40010ALF1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC40010ALF1T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.