verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-10 FRL Unit (GC40010ALF2WTK)

The AirTAC GC400-10 FRL Unit (GC40010ALF2WTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$176.46 $183.96Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-10 drain, gauge and thread option on one page All GC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC400-10 FRL Unit (GC40010ALF2WTK)

The GC40010ALF2WTK is an AirTAC GC-series three-unit F.R.L. combination: a separate filter, regulator and lubricator assembled as one air-preparation set. This configuration is the 400 size with a NPT3/8 (3/8 in) port, NPT thread. The filter element is the fine 5 um grade (W) and the drain is automatic, so condensate is expelled without manual attention. The regulator is the low-pressure type with an embedded square gauge scaled in psi, and a reverse/check valve is fitted. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing). The bowl on the filter section is PC (polycarbonate) at this size.

This is a genuine AirTAC part. The GC family is available in 200, 300, 400 and 600 sizes with port sizes from 1/8 in to 1 in, and with choices of drain type, filter grade (40 um standard or 5 um), gauge type and scale, thread (three thread types (NPT on this code)), low-pressure regulator type, reverse/check valve and bracket. Flow is published as curves rather than a single rated figure, so we confirm datasheet and flow figures for your application on request.

AirTAC GC400-10 FRL Unit (GC40010ALF2WTK) Technical Specifications

ModelAirTAC GC400-10 FRL Unit (GC40010ALF2WTK)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-10 FRL Unit (GC40010ALF2WTK)

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-10 FRL Unit (GC40010ALF2WTK) Is Used

precision_manufacturing

Pneumatic press station

Feeds a bench-mounted pneumatic press or clamping fixture: the 5 um element protects the valve and cylinder seals, the low-pressure regulator holds a gentle working pressure for delicate forming, and the lubricator mists oil to the cylinder. The psi gauge gives the operator a direct reading.

conveyor_belt

Packaging and cartoning line

Supplies the air cylinders on a carton-forming or case-sealing conveyor, where the automatic drain copes with condensate on a line that runs unattended and the check valve keeps the actuators from collapsing during a supply dip.

factory

Plant air drop for assembly cells

Installed as the preparation set at an assembly-cell air drop: filtration, regulation and lubrication in one 3/8 in unit ahead of the cell's directional valves and air tools, with the included bracket mounting the set to the machine frame.

Is the AirTAC GC400-10 FRL Unit (GC40010ALF2WTK) the Right Station?

Start with the size and port: the 400 size carries a 3/8 in port, and the step up or down through 200/300/400/600 changes both the port and the flow capacity, so match the size to the air demand of the downstream circuit. Then set the options that this code fixes: the 5 um (W) element where finer filtration than the 40 um standard is needed; the automatic drain where the unit is not visited daily; the low-pressure regulator type where the circuit works below the standard adjustment band; and the square gauge in psi (MPa and bar scales are also available). The reverse/check valve (K) holds downstream pressure if the supply is interrupted, and the bracket is included for mounting.

Because flow is published as curves and not as a single rated number, ask us to confirm sizing against your application before ordering. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G (BSPP) and NPT versions are catalogue options to order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

AirTAC GC400-10 FRL Unit (GC40010ALF2WTK) FAQ

AirTAC publishes flow for this series as curves, not as a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the flow and datasheet figures for the 400 size at your working pressure before you order.

Both are read from the code: the A after the port is the automatic drain, which expels collected condensate without manual attention, and the W is the 5 um filter grade, finer than the 40 um standard. The 40 um grade with a manual or differential-pressure drain is available on other GC400 codes if your circuit prefers them.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC400-10 FRL Unit (GC40010ALF2WTK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC40010ALF2WTK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.