AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-10 FRL Unit (GC40010ALNT)

The AirTAC GC400-10 FRL Unit (GC40010ALNT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$161.52 $169.02Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-10 drain, gauge and thread option on one page All GC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC400-10 FRL Unit (GC40010ALNT)

GC40010ALNT is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator built up as one 400-size set on NPT 3/8-inch ports. In use it removes water and particulate from the compressed air with the standard 40 um element, sets the downstream working pressure, and meters oil mist to the actuators and tools that follow. This code carries the automatic-drain filter bowl (A), the low-pressure regulator type (L) and no gauge (N); the filter and lubricator bowls are polycarbonate at size 400. The medium is compressed air only, maximum working pressure is 1.0 MPa (145 psi), and operating temperature is -5 to 70 C (non-freezing).

This is a genuine AirTAC part sold by a US distributor. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow for the series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing on request.

AirTAC GC400-10 FRL Unit (GC40010ALNT) Technical Specifications

ModelAirTAC GC400-10 FRL Unit (GC40010ALNT)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-10 FRL Unit (GC40010ALNT)

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-10 FRL Unit (GC40010ALNT) Is Used

valve

Water-plant valve actuation

Feeds filtered, lubricated, pressure-set air to the quarter-turn actuators driving butterfly valves on a treatment-plant skid, with the automatic drain keeping the filter bowl clear during unattended operation.

factory

Bottling-line carton sealers

Supplies the sealing and flap-fold cylinders on an end-of-line packaging machine, combining water removal, pressure setting and oil mist in one 3/8-inch set.

conveyor_belt

Parcel-hub diverters

Powers the diverter gates that push parcels between conveyor runs in a sorting hub, where the low-pressure regulator type matches the gate cylinders' working span.

Is the AirTAC GC400-10 FRL Unit (GC40010ALNT) the Right Station?

Choose the 400 size when 3/8-inch supply piping is already in the line; lighter demand can drop to size 300 and heavier lines step to 600. Because flow is published as curves, not a single rating, we confirm sizing against your air consumption before you order. The automatic drain here (A) empties the filter bowl unattended; manual (M) and differential-pressure (blank) versions are orderable alternatives. The element grade is the standard 40 um (W gives 5 um), and the L in this code selects the low-pressure regulator type - confirm its adjustment range with us on request. No gauge is fitted (N), though gauge options can be specified in the code; This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

AirTAC GC400-10 FRL Unit (GC40010ALNT) FAQ

AirTAC publishes flow for the GC series as characteristic curves across pressure ranges, not as a single rated figure, so no one number is honest to quote. Send us your working pressure and air consumption and we will confirm the flow and full datasheet on request before you order.

A selects the automatic drain, which empties the filter bowl without daily attention. The same 400-size, NPT3/8 set is also available with a manual drain (M) or the differential-pressure drain (blank) - just change that position in the code when you order.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC400-10 FRL Unit (GC40010ALNT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC40010ALNT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.