AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-10 FRL Unit (GC40010C1T)

The AirTAC GC400-10 FRL Unit (GC40010C1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$155.22 $162.72Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-10 drain, gauge and thread option on one page All GC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC400-10 FRL Unit (GC40010C1T)

The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, so incoming compressed air is cleaned, regulated and lubricated in one installation. This GC40010C1T is the 400 size with 3/8" NPT ports, the standard differential-pressure drain on the polycarbonate filter bowl, the standard 40 um filter element and a round external gauge with MPa scale, so operators can read the regulated pressure directly at the unit.

This is a genuine AirTAC part. The G-series covers 200, 300, 400 and 600 sizes with a choice of thread (NPT on this code), drain types, filter grades and gauge scales, with a maximum working pressure of 1.0 MPa (145 psi). Flow figures are published as curves rather than a single rating, so ask us to confirm sizing and the full datasheet against your application before ordering.

AirTAC GC400-10 FRL Unit (GC40010C1T) Technical Specifications

ModelAirTAC GC400-10 FRL Unit (GC40010C1T)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-10 FRL Unit (GC40010C1T)

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-10 FRL Unit (GC40010C1T) Is Used

valve

Process control valve skids

Supplies positioner and actuator air on valve skids, with the MPa gauge letting operators check regulated set pressure at a glance.

science

Environmental test chambers

Prepares air for chamber door actuators and spray or purge circuits, where the 40 um element and stable regulation protect the test process.

local_shipping

Fleet maintenance bays

Feeds truck-lift platforms and pneumatic hand tools in vehicle workshops, with lubricated air extending tool service life.

Is the AirTAC GC400-10 FRL Unit (GC40010C1T) the Right Station?

The 400 size with 3/8" NPT ports suits lines with substantial air demand; step down to 300 or up to 600 as your flow curve requires. This version carries the default differential-pressure drain and the standard 40 um element; order the A (automatic) or M (manual) drain and the W 5 um element if your application calls for them. The regulator adjusts from 0.15 to 0.9 MPa (20-130 psi) with this drain type. C1 gives you a round external gauge in MPa; psi and bar scales are alternatives. Operating temperature is -5 to 70 C, non-freezing. Flow is published as curves, not a single rating, so confirm sizing with us before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

AirTAC GC400-10 FRL Unit (GC40010C1T) FAQ

AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the flow curve and correct size from the datasheet on request.

C is the round external gauge and 1 is the MPa scale, so this set reads regulated pressure in MPa. If you prefer psi or bar, or the embedded square gauge instead of the external round one, those are catalogue options on the same 400-size, 3/8" NPT unit.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC400-10 FRL Unit (GC40010C1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC40010C1T and will confirm price, availability and lead time — usually within 7 hours.