verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-10 FRL Unit (GC40010C2T)

The AirTAC GC400-10 FRL Unit (GC40010C2T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$155.22 $162.72Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-10 drain, gauge and thread option on one page All GC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC400-10 FRL Unit (GC40010C2T)

The AirTAC GC40010C2T is a size 400 three-unit F.R.L. combination that filters, regulates and lubricates compressed air from one assembled set: a separate filter, a separate pressure regulator and a separate oil-mist lubricator. This configuration is decodes as a NPT3/8 (3/8 in) port with NPT thread, a 40 um standard filter element, a differential-pressure drain on the filter bowl, a standard regulator with a 0.15-0.9 MPa (20-130 psi) adjustment range, and a round pressure gauge with a psi scale. The polycarbonate bowls suit the -5 to 70 C (non-freezing) operating range, and the maximum inlet pressure is 1.0 MPa (145 psi).

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with port options from 1/8 in to 1 in, thread options three thread types (NPT on this code), filter grades 40 um standard or 5 um (code W), drain choices of differential-pressure, automatic or manual, and gauge scales in MPa, psi or bar. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application on request.

AirTAC GC400-10 FRL Unit (GC40010C2T) Technical Specifications

ModelAirTAC GC400-10 FRL Unit (GC40010C2T)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-10 FRL Unit (GC40010C2T)

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-10 FRL Unit (GC40010C2T) Is Used

factory

General plant air supply for production halls

Installed at the drop from a plant air main, the GC40010C2T removes water and particulate, holds a set working pressure for the tools and actuators on the line, and carries oil mist downstream to keep air cylinders and valves lubricated in daily service.

conveyor_belt

Conveyor and packaging line air preparation

On packaging and conveyor systems with pneumatic diverters, clamps and lift cylinders, this three-unit set gives one point of clean, regulated, lubricated air for the whole section, with the psi gauge letting operators verify line pressure at a glance.

engineering

Machine-build OEM pneumatic circuits

This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Is the AirTAC GC400-10 FRL Unit (GC40010C2T) the Right Station?

Start with the size and port: the 400 size with a 3/8 in NPT port sits in the middle of the GC range (200/300/400/600), so step up or down if your line flow demand points to a different port size. The 40 um standard element is the usual choice for general plant air; choose the 5 um (W) grade only where downstream equipment needs finer particulate removal. The differential-pressure drain (the default) flushes the bowl automatically as pressure differentials build; specify automatic (A) or manual (M) drain instead if your maintenance routine calls for it. The round gauge with a psi scale is fitted on this unit; MPa or bar scales are the alternatives. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G (BSPP) and NPT are catalogue thread options to order. A mounting bracket is included.

Because flow is published as curves and not as a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

AirTAC GC400-10 FRL Unit (GC40010C2T) FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a rated flow number for this unit. Tell us your application and required flow, and we will confirm the datasheet figures and check the sizing for you on request.

In the GC code, C at the gauge position means an external round gauge is fitted instead of the standard embedded square gauge, and the scale digit 2 means psi. If you prefer the embedded square gauge, or a scale in MPa or bar, those are catalogue options on the same unit.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC400-10 FRL Unit (GC40010C2T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC40010C2T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.