AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-10 FRL Unit (GC40010F1T)

The AirTAC GC400-10 FRL Unit (GC40010F1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$155.22 $162.72Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-10 drain, gauge and thread option on one page All GC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC400-10 FRL Unit (GC40010F1T)

The AirTAC GC series combines a separate air filter, pressure regulator and oil-mist lubricator in one three-piece F.R.L. set. The GC40010F1T is set up for 3/8 in NPT ports in size 400, uses the standard 40 um filter element with the default differential-pressure drain, and is ordered with the square pressure gauge on an MPa scale, the compact reading panel the series fits on the regulator.

This is a genuine AirTAC part. The series is available in sizes 200, 300, 400 and 600, with three thread types (NPT on this code), 40 um or 5 um filtration, and MPa, psi or bar gauge scales. Maximum working pressure is 1.0 MPa (145 psi) with an operating range of -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm sizing and full datasheet figures on request.

AirTAC GC400-10 FRL Unit (GC40010F1T) Technical Specifications

ModelAirTAC GC400-10 FRL Unit (GC40010F1T)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-10 FRL Unit (GC40010F1T)

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-10 FRL Unit (GC40010F1T) Is Used

precision_manufacturing

Vertical Machining Center Chip Conveyors

Condition the air driving the paddle cylinders and gates of a chip conveyor on a vertical machining center, all from one 3/8 in conditioning set at the machine base.

build

Panel Saw Clamp Beam

Feed the hold-down clamp beam of a panel saw with filtered, regulated and lubricated air so saw-duty cylinders keep consistent lubrication through repeated cutting cycles.

science

Lab Automation Actuator Rail

Supply the lift-and-press cylinders on a laboratory automation rail, where the square MPa gauge gives technicians a compact, readable pressure reference at the manifold.

Is the AirTAC GC400-10 FRL Unit (GC40010F1T) the Right Station?

Stay with size 400 at 3/8 in NPT for medium-flow circuits, or step to size 300 or 600 where the catalogue flow curves show a better match. The 40 um element covers general machine-air duty; choose a W code for 5 um filtration. The F option gives the square gauge reading in MPa; round gauges and psi or bar scales are on other codes.

This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The filter bowl is polycarbonate at size 400 with differential-pressure drain. Because flow is published only as curves, send us your application and we will confirm the right size before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

AirTAC GC400-10 FRL Unit (GC40010F1T) FAQ

We do not quote a rated flow figure because AirTAC publishes G-series flow as curves, not a single number. Tell us your line's duty and we will confirm capacity and sizing from the datasheet on request before you order.

Both are size 400, three-unit F.R.L. sets for 3/8 in NPT with a 40 um element. F1 specifies the square gauge on an MPa scale, while C1 specifies the external round gauge in MPa. Pick the style your panel layout prefers; both read the same pressure.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC400-10 FRL Unit (GC40010F1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC40010F1T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.