AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-10 FRL Unit (GC40010MLF2TK)

The AirTAC GC400-10 FRL Unit (GC40010MLF2TK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$170.15 $177.65Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-10 drain, gauge and thread option on one page All GC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC400-10 FRL Unit (GC40010MLF2TK)

The GC400-10 is a three-piece AirTAC F.R.L. combination: a separate filter, pressure regulator and oil-mist lubricator assembled as one air-preparation set. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The square pressure gauge fitted here reads in psi, a reverse/check valve is included, and the set ships with its mounting bracket.

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, and options include automatic or differential-pressure drains, a 5 um filter element, alternative gauge scales and G or NPT threads. Rated flow is published as curves rather than a single figure, so ask us to confirm the datasheet numbers for your application before ordering. Order code GC40010MLF2TK has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC400-10 FRL Unit (GC40010MLF2TK) Technical Specifications

ModelAirTAC GC400-10 FRL Unit (GC40010MLF2TK)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-10 FRL Unit (GC40010MLF2TK)

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-10 FRL Unit (GC40010MLF2TK) Is Used

factory

Plant air drop for an assembly line

Installed at the 3/8 inch take-off feeding a production cell, the set cleans the shop air, holds the circuit at the low working pressure the tooling calls for, and carries oil mist downstream to keep air cylinders and valves running smoothly.

conveyor_belt

Pneumatic stops and diverters on a conveyor run

Mounted on the bracket beside a conveyor section, the unit supplies filtered, regulated and lubricated air to the stopper cylinders and gate actuators that index cartons along the line, with the psi gauge giving operators a visible setpoint.

build

Air supply to pneumatic machine tools

Fitted ahead of clamps, presses and air motors on a machine bench, the combination removes water and particulate at the 40 um grade, regulates the supply at low pressure, and mists oil into the air so the tooling's moving parts stay lubricated.

Is the AirTAC GC400-10 FRL Unit (GC40010MLF2TK) the Right Station?

Start with the port step: this unit is size 400 with a 3/8 inch NPT port, one step up from the 300/1/4 inch class, so pick it when your line plumbing is 3/8 inch and your air demand sits above what a smaller set serves. The manual drain here means someone opens the bowl drain during checks; choose the automatic or differential-pressure drain variant if the unit sits where regular draining is impractical. The 40 um element is the standard grade for general plant air; specify the W code for the 5 um element where finer particulate removal matters. The fitted square gauge reads in psi; MPa and bar scales and an external round gauge are order options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Because rated flow is published only as curves, not a single number, send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

AirTAC GC400-10 FRL Unit (GC40010MLF2TK) FAQ

AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote one number. Send us your application details and we will confirm the flow and datasheet figures for the GC400-10 on request before you order.

The M in the model code sets a manual drain: the bowl is emptied by hand during routine checks. If the unit will be mounted where regular draining is awkward, order the automatic (A) or differential-pressure (blank) drain variant of the same GC400 set instead.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC400-10 FRL Unit (GC40010MLF2TK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC40010MLF2TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.