The AirTAC GC400-10 FRL Unit (GC40010NT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC40010NT is a genuine AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator working together as one conditioned-air supply. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. No pressure gauge is fitted, as coded by N. The regulator adjustment range is 0.15-0.9 MPa (20-130 psi) with the differential-pressure drain, the maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C.
This is a genuine AirTAC part. The G-series F.R.L. combination is offered in 200, 300, 400 and 600 sizes with a choice of 40 um standard or 5 um (W) filtration, differential-pressure, automatic or manual draining, gauged or non-gauged versions, and three thread types (NPT on this code). On the 400 size the filter and lubricator bowls are polycarbonate (PC). Flow for the series is published as curves rather than a single rated figure, so we confirm sizing and datasheet figures on request.
| Model | AirTAC GC400-10 FRL Unit (GC40010NT) |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT3/8" · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-10 |
| Build order | Filter → regulator → lubricator |
Conditions shop air feeding the tool-clamp, tool-changer and chip-door cylinders on a CNC machining center, with the regulator set to the pressure the machine builder specifies and the lubricator metering oil to the actuator seals.
Feeds filtered, regulated and lubricated air to the case-erector and taping-head cylinders on a carton-sealing line, where condensate from the compressor would otherwise reach the valves and seals.
Supplies conditioned air to spray guns in a paint booth: the filter removes water and particles before the gun, the regulator holds a steady set pressure and the lubricator is adjusted or left dry according to the gun manufacturer's requirement.
Size 400 with 3/8 in NPT ports sits in the upper-middle of the G-series range: step down to 300 or up to 600 depending on the air demand at the point of use. Filtration here is the standard 40 um element; choose the W version (GC40010NW) where 5 um filtration is required. The drain on this model is differential-pressure, the series default; automatic (A) and manual (M) drain versions are also available. Because the code ends in N, no gauge is supplied; gauged GC versions carry an embedded square gauge with MPa, psi or bar scale options.
This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Sizing against flow is the one decision we recommend verifying with us first: published flow data takes the form of curves, not a single rating, so ask us to confirm the right size before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.
AirTAC publishes G-series flow as performance curves rather than a single rated figure, so we do not quote one number. Send us your inlet pressure, port size and downstream demand and we will confirm the appropriate size and the datasheet figures on request.
Yes. N codes a non-gauged version, so the regulator is adjusted without a supplied gauge. Gauged GC versions carry an embedded square gauge with a choice of MPa, psi or bar scale, and these are orderable options in the same series.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.