The AirTAC GC400-10 FRL Unit (GC40010NTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC40010NTK is a genuine AirTAC G-series three-unit F.R.L. combination - separate filter, regulator and lubricator - fitted with a reverse (check) valve as coded by the trailing K. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. No pressure gauge is fitted, as coded by N. With the differential-pressure drain the regulator adjustment range is 0.15-0.9 MPa (20-130 psi), the maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C.
This is a genuine AirTAC part. The G-series F.R.L. combination is offered in 200, 300, 400 and 600 sizes with 40 um standard or 5 um (W) filtration, differential-pressure, automatic or manual draining, gauged or non-gauged versions, with or without the K reverse valve, and three thread types (NPT on this code). On the 400 size the filter and lubricator bowls are polycarbonate (PC). Flow is published as curves rather than a single rated figure, so we confirm sizing and datasheet figures on request.
| Model | AirTAC GC400-10 FRL Unit (GC40010NTK) |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT3/8" · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-10 |
| Build order | Filter → regulator → lubricator |
Conditions the air feeding gate and stopper cylinders along a bottling conveyor, with the check valve in the supply keeping the circuit as specified while the filter protects the diverters from condensate carryover.
Supplies regulated, lubricated air to the clamping and pressing cylinders of an assembly cell, where the coded reverse valve forms part of the circuit and the regulator holds the pressure the press tooling is set up for.
Feeds a workshop bench used to function-test pneumatic valves and actuators, providing clean, regulated and lubricated air at a controlled set pressure with the check valve included as coded.
Decode the K position first: GC40010NTK adds a reverse (check) valve to the same size 400, 3/8 in NPT, 40 um, differential-drain, non-gauged set as GC40010N. Choose the K version where the circuit calls for a check valve in the supply; otherwise the standard set is the equivalent choice.
Filtration is the standard 40 um element here - step to the W version (GC40010NWK) for 5 um. Automatic (A) and manual (M) drains are available in place of the differential-pressure default. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Since series flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.
Flow for the G-series is published as curves, not as a single rated number, so we do not state one figure here. Give us your inlet pressure and the air demand downstream and we will confirm the sizing and the datasheet curves on request.
K codes that a reverse (check) valve is fitted to the set. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.