AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC600-20 FRL Unit (GC60020AC2WT)

The AirTAC GC600-20 FRL Unit (GC60020AC2WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/4" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$252.49 $259.99Save 2% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC600-20 drain, gauge and thread option on one page All GC600-20 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC600-20 FRL Unit (GC60020AC2WT)

The GC600-20 is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one set. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C (non-freezing). At size 600 the filter bowl is aluminium alloy.

This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600 with matching port sizes, and options include the 40 um standard or 5 um (W) filter grade, differential-pressure, automatic or manual draining, gauge choice and scale (MPa, psi or bar), and G (BSPP) or NPT threads in place of the NPT standard. Flow figures for this series are published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering. Order code GC60020AC2WT has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC600-20 FRL Unit (GC60020AC2WT) Technical Specifications

ModelAirTAC GC600-20 FRL Unit (GC60020AC2WT)
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/4" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialAluminium alloy
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC600-20 FRL Unit (GC60020AC2WT)

GC600G-series F.R.L. combination, 600 body — sets the port range.
20Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-20 filter, GR600-20 regulator and GL600-20 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT3/4" · 5 µm
One size downGC400
Two-unit equivalentGFC600-20
Build orderFilter → regulator → lubricator

Where the AirTAC GC600-20 FRL Unit (GC60020AC2WT) Is Used

factory

Automotive paint shop air drops

At a 3/4 in main drop feeding paint booths, the 5 um element and regulator deliver cleaned, pressure-controlled air to spray equipment, while the lubricator mists oil for downstream air tools.

conveyor_belt

Packaging line cylinder supply

On a cartoning or case-packing conveyor line, this F.R.L. set conditions the plant air feeding pneumatic cylinders and grippers, holding a stable set pressure and lubricating the actuators.

precision_manufacturing

Pneumatic press cell

For a workshop pneumatic press or clamping cell on a 3/4 in supply, the combination filters water and particles from the compressed air, regulates working pressure, and oils the air circuit.

Is the AirTAC GC600-20 FRL Unit (GC60020AC2WT) the Right Station?

Start with the port and size step: this is the size 600 unit with a 3/4 in NPT port, the largest step in the GC range (200/300/400/600), so size up or down against the air demand of the line. The 5 um (W) element suits points of use that need finer filtration than the 40 um standard; the automatic drain on this unit evacuates condensate without manual attention, while manual and differential-pressure drains remain available in the family. The regulator is the standard type, adjustable 0.15-0.9 MPa (20-130 psi), and the gauge on this configuration is the external round type with a psi scale; square embedded gauges and MPa or bar scales are the other catalogue choices. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

One honest note on sizing: flow for this series is published as curves, not as a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the sizing and datasheet figures before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-20 regulator with a GF600-20 filter on that branch.

AirTAC GC600-20 FRL Unit (GC60020AC2WT) FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not state a number here. Send us your application details and we will confirm the flow and datasheet figures for this 3/4 in, size 600 unit on request.

This GC600-20 is ordered with the automatic drain (code A), which discharges condensate from the filter bowl without operator attention. The catalogue also offers manual draining (code M) and the differential-pressure drain as the default, so you can choose the drain type that matches how the unit is maintained.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC600-20 FRL Unit (GC60020AC2WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC60020AC2WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.