AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC600-20 FRL Unit (GC60020AF2WT)

The AirTAC GC600-20 FRL Unit (GC60020AF2WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/4" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$252.49 $259.99Save 2% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC600-20 drain, gauge and thread option on one page All GC600-20 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC600-20 FRL Unit (GC60020AF2WT)

The GC600-20 is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one set. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi), and the lubricator delivers oil mist downstream to keep air tools and cylinders working. At size 600 the filter bowl is aluminium alloy, and the maximum inlet pressure is 1.0 MPa (145 psi) with an operating temperature range of -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with port sizes from 1/8" to 1", and options include manual or differential-pressure drains, the 40 um standard element, gauge scale in MPa, psi or bar, a reverse/check valve, and G (BSPP) or NPT threads in place of the NPT standard. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application. Order code GC60020AF2WT has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC600-20 FRL Unit (GC60020AF2WT) Technical Specifications

ModelAirTAC GC600-20 FRL Unit (GC60020AF2WT)
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/4" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialAluminium alloy
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC600-20 FRL Unit (GC60020AF2WT)

GC600G-series F.R.L. combination, 600 body — sets the port range.
20Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-20 filter, GR600-20 regulator and GL600-20 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT3/4" · 5 µm
One size downGC400
Two-unit equivalentGFC600-20
Build orderFilter → regulator → lubricator

Where the AirTAC GC600-20 FRL Unit (GC60020AF2WT) Is Used

factory

Central plant air preparation

Installed at the take-off from a plant air receiver or main header, the filter cleans water and particulate from the compressed air, the regulator holds a steady downstream pressure, and the lubricator feeds oil mist to the tools and actuators served from that line.

conveyor_belt

Packaging and conveyor actuation

Mounted ahead of the valve manifold on a packaging or conveyor line, this unit supplies filtered, regulated and lubricated air to the cylinders that clamp, push and divert product, with the automatic drain handling condensate without daily attention.

engineering

Pneumatic press and fixture circuits

Fitted at the supply to a pneumatic press, clamping fixture or workholding circuit, it protects the directional valves and cylinders from water and 5 um-level particulate, holds the set working pressure on the psi gauge, and keeps lubrication mist in the air stream.

Is the AirTAC GC600-20 FRL Unit (GC60020AF2WT) the Right Station?

Start with the port and size step: this unit is size 600 with a NPT3/4 port, the largest step in the range - step down to 200/300/400 if your line runs at lower flow. Choose the drain to match how the unit is attended: automatic (this unit) suits unattended or hard-to-reach installations, manual suits supervised points, and differential-pressure is the default. This unit carries the 5 um element (code W); the 40 um standard element is the usual choice for general plant air, with 5 um for finer protection. The embedded square gauge here reads in psi; MPa and bar scales are available, and an external round gauge is optional. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow for this series is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-20 regulator with a GF600-20 filter on that branch.

AirTAC GC600-20 FRL Unit (GC60020AF2WT) FAQ

AirTAC publishes flow for this series as performance curves rather than a single rated figure, so no single flow number can be quoted here. Ask us and we will confirm the datasheet and the curve for the GC600 size, then check it against your application's flow demand before you order.

The W in the code GC60020AF2WT selects the 5 um filter element instead of the 40 um standard, giving finer particulate protection; the A selects the automatic drain, which discharges condensate from the bowl without manual attention. If your air is already reasonably clean, the 40 um element, or a manual or differential-pressure drain, are the alternative decodable choices in this series.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC600-20 FRL Unit (GC60020AF2WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC60020AF2WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.