The AirTAC GC600-20 FRL Unit (GC60020AF3T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/4" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC60020AF3T is a three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator that clean, regulate and oil-mist lubricate compressed air as one set. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Maximum working pressure is 1.0 MPa (145 psi), the operating temperature range is -5 to 70 C (non-freezing), and with the automatic drain the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi). The 600-size bowls are aluminium alloy.
This is a genuine AirTAC part from the G series, available in sizes 200 through 600 with a choice of ports, threads, drains, filter grades and gauge scales. Flow is published only as curves rather than a single rating, so we confirm flow and datasheet figures on request before you order.
| Model | AirTAC GC600-20 FRL Unit (GC60020AF3T) |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — square, bar scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| 20 | Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-20 filter, GR600-20 regulator and GL600-20 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · PT3/4" · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-20 |
| Build order | Filter → regulator → lubricator |
Supplies clean, regulated and lubricated utility air to the bench valves and actuated fixtures on a pilot-plant or laboratory manifold, with the bar gauge matching European-style instrumentation.
Runs the pneumatic gate cylinders and hold-down clamps on a panel-saw and press line in a woodworking shop, fed from a 3/4 in branch header.
Conditions air for the actuator test bench used to cycle fire-door closers and HVAC dampers, where the regulator holds a fixed set point for repeatable test strokes.
Use size 600 with the 3/4 in port when branch demand outruns a 400-size unit; drop to 300 or 400 for lighter legs of the distribution system. This code pairs the standard 40 um element with a bar-scaled square gauge (F3), the readout to pick when your plant instruments and drawings are in bar. The automatic drain keeps condensate off the line without daily attention, useful at elevated or out-of-reach mounting points. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Because flow appears as curves rather than one rated number, ask us to confirm sizing against your application before ordering.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-20 regulator with a GF600-20 filter on that branch.
Design from the curves: AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not state a number here. Give us your demand and pressure and we will confirm the sizing against the datasheet on request before you order.
The trailing code letters set both choices. F3 on this model is the square gauge in bar; use F1 for MPa or F2 for psi. The absence of W means the standard 40 um element; the corresponding W code orders the optional 5 um element in the same 600-20, automatic-drain configuration.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.