verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC600-20 FRL Unit (GC60020AF3WT)

The AirTAC GC600-20 FRL Unit (GC60020AF3WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/4" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$252.49 $259.99Save 2% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC600-20 drain, gauge and thread option on one page All GC600-20 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC600-20 FRL Unit (GC60020AF3WT)

The GC600 is AirTAC's three-unit F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator piped together to condition compressed air at one station. This GC60020AF3WT is the 600 size with 3/4 in. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Maximum working pressure is 1.0 MPa (145 psi), and with the automatic drain the regulator adjustment range is 0.15-0.9 MPa (20-130 psi).

This is a genuine AirTAC part. At the 600 size the filter bowl is aluminium alloy, and the unit is rated for -5 to 70 C (non-freezing). AirTAC's G series also covers 200, 300 and 400 sizes with manual or differential-pressure drains, 40 um or 5 um elements, other gauge scales and G or NPT threads, so a matching unit can be specified for smaller lines. Flow for this size is published as curves rather than a single rating; ask us and we will confirm the datasheet figures for your application.

AirTAC GC600-20 FRL Unit (GC60020AF3WT) Technical Specifications

ModelAirTAC GC600-20 FRL Unit (GC60020AF3WT)
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/4" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialAluminium alloy
Pressure gaugeFitted — square, bar scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC600-20 FRL Unit (GC60020AF3WT)

GC600G-series F.R.L. combination, 600 body — sets the port range.
20Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-20 filter, GR600-20 regulator and GL600-20 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT3/4" · 5 µm
One size downGC400
Two-unit equivalentGFC600-20
Build orderFilter → regulator → lubricator

Where the AirTAC GC600-20 FRL Unit (GC60020AF3WT) Is Used

conveyor_belt

Bottling line air prep

A bottling hall's filler and capper actuators run continuously and generate condensate; this 5 um, automatic-drain station filters, regulates and lubricates the air feeding the line without an operator having to drain bowls each shift.

precision_manufacturing

CNC machining cell

Supplies filtered, regulated and lubricated air to pneumatic clamps and tool-change cylinders on a machining centre, with the bar-scale gauge giving a quick visual check of the setpoint.

settings_input_component

Case-packing machinery

On a case packer or palletizer, the three separate units let maintenance service the filter, adjust the regulator and top up the lubricator independently instead of replacing a complete set.

Is the AirTAC GC600-20 FRL Unit (GC60020AF3WT) the Right Station?

The 600 size carries the largest ports in the G series: 3/4 in. (code 20) or 1 in. (code 25), while the 200/300/400 sizes cover 1/8 to 1/2 in. Match the port to your piping and let flow decide, not guesswork. Drain type is a real choice here: automatic (this unit, code A) expels condensate on its own, manual (M) needs an operator, and the blank default is a differential-pressure drain. Filter grade is 5 um on this version; the standard element is 40 um if your application tolerates coarser filtration. Gauge is a square type with a bar scale; MPa, psi scales and a round external gauge are alternatives. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Flow is published by AirTAC as curves, not a single rated number, so send us your flow and pressure requirement and we will confirm the datasheet curve and correct size before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-20 regulator with a GF600-20 filter on that branch.

AirTAC GC600-20 FRL Unit (GC60020AF3WT) FAQ

AirTAC publishes flow for the G series as curves, not as a single rated figure, so we do not quote a number here. Send us your flow and pressure requirement and we will confirm the datasheet curve for this 3/4 in. size before you order.

A means the filter bowl drains automatically, so condensate is expelled without an operator; the catalogue alternatives are M (manual) and blank (differential-pressure), and the drain type also sets the regulator adjustment range, which is 0.15-0.9 MPa (20-130 psi) for this automatic-drain version. W means the 5 um filter element instead of the standard 40 um.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC600-20 FRL Unit (GC60020AF3WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC60020AF3WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.