verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC600-25 FRL Unit (GC60025ALC2TK)

The AirTAC GC600-25 FRL Unit (GC60025ALC2TK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$267.42 $274.92Save 2% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC600-25 drain, gauge and thread option on one page All GC600-25 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC600-25 FRL Unit (GC60025ALC2TK)

The GC600-25 is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one 3-piece set. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The filter section carries the standard 40 um element with an automatic drain, so collected condensate is discharged without manual attention. The regulator is the low-pressure type and is fitted with an external round gauge reading in psi; a reverse/check valve is also fitted to hold downstream settings when upstream pressure is lost. At size 600, the filter bowl is aluminium alloy. Max inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC family is also available in sizes 200, 300 and 400 with smaller ports, PC bowls, manual or differential-pressure drains, a 5 um (W) filter element, embedded square gauges with MPa/psi/bar scales, and G or NPT thread options. Flow is published as curves rather than a single rated figure, so we confirm the datasheet and sizing figures on request. Order code GC60025ALC2TK has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC600-25 FRL Unit (GC60025ALC2TK) Technical Specifications

ModelAirTAC GC600-25 FRL Unit (GC60025ALC2TK)
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialAluminium alloy
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC600-25 FRL Unit (GC60025ALC2TK)

GC600G-series F.R.L. combination, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT1" · 40 µm
One size downGC400
Two-unit equivalentGFC600-25
Build orderFilter → regulator → lubricator

Where the AirTAC GC600-25 FRL Unit (GC60025ALC2TK) Is Used

conveyor_belt

Bottling and canning line air preparation

A high-volume packaging hall feeding 1 in air mains to case packers, labelers and conveyor actuators: filtered, regulated and lubricated air in one set, with the automatic drain handling condensate through long production shifts.

factory

Foundry and steel plant actuation circuits

Large-bore cylinders and clamps on casting and material-handling equipment supplied from a plant ring main, where the low-pressure regulator setting, psi gauge and check valve keep downstream actuators held and readable at the cell.

local_shipping

Truck and trailer assembly plant tool air

A chassis line running impact wrenches, torque stations and pneumatic presses off a 1 in drop: the 40 um filter protects the tools, the lubricator mists them continuously, and the regulator holds a stable setting per station.

Is the AirTAC GC600-25 FRL Unit (GC60025ALC2TK) the Right Station?

Step up or down through the GC sizes (200 / 300 / 400 / 600) against the port and flow your line needs; this unit is the 600 size on a 1 in NPT port. Drain choice is real: automatic (this unit), manual, or the differential-pressure default. Filter grade is 40 um standard or 5 um with the W code. Gauges: an embedded square gauge is standard, an external round gauge is optional, with MPa, psi or bar scales - this unit has the round gauge in psi. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Because flow is published as curves and not a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.

AirTAC GC600-25 FRL Unit (GC60025ALC2TK) FAQ

AirTAC publishes flow for this family as curves, not as a single rated number, so we do not quote a figure here. Send us your line pressure, downstream demand and port size and we will confirm the flow and sizing from the datasheet on request before you order.

The A in GC60025ALC2TK selects the automatic drain, so the filter bowl discharges condensate on its own instead of the manual or differential-pressure options. The C2 selects the optional external round gauge with a psi scale (MPa and bar scales are also available); the embedded square gauge is the standard fitting.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC600-25 FRL Unit (GC60025ALC2TK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC60025ALC2TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.