verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC600-25 FRL Unit (GC60025ALF2WTK)

The AirTAC GC600-25 FRL Unit (GC60025ALF2WTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$267.42 $274.92Save 2% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC600-25 drain, gauge and thread option on one page All GC600-25 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC600-25 FRL Unit (GC60025ALF2WTK)

The GC600-25 is a three-piece AirTAC F.R.L. combination: a separate filter, a pressure regulator and an oil-mist lubricator assembled as one air-preparation set for compressed air. In this configuration the 1 in NPT port serves larger supply lines, the filter element is the fine 5 um grade (W), the bowl drains automatically, the regulator is the low-pressure type, an embedded square gauge with psi scale is fitted, and a reverse/check valve is included. The filter bowl on this 600 size is aluminium alloy, and a mounting bracket is included.

This is a genuine AirTAC part from the GC series, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, thread options three thread types (NPT on this code), drain choices, 40 um standard or 5 um fine filtration, gauge scales in MPa, psi or bar, and optional reverse/check valves. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request. Order code GC60025ALF2WTK has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC600-25 FRL Unit (GC60025ALF2WTK) Technical Specifications

ModelAirTAC GC600-25 FRL Unit (GC60025ALF2WTK)
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialAluminium alloy
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC600-25 FRL Unit (GC60025ALF2WTK)

GC600G-series F.R.L. combination, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT1" · 5 µm
One size downGC400
Two-unit equivalentGFC600-25
Build orderFilter → regulator → lubricator

Where the AirTAC GC600-25 FRL Unit (GC60025ALF2WTK) Is Used

factory

Automotive paint shop supply drop

Feeds a spray-booth air drop where fine 5 um filtration protects finish quality, the automatic drain keeps condensate off the line during shifts, and the low-pressure regulator holds the gentle pressure spray guns need.

conveyor_belt

Food and beverage packaging line

Prepares air for case packers and labeler actuators on a 1 in header: the filter removes water and particles, the lubricator mists oil for cylinder life, and the check valve holds downstream pressure if supply dips.

engineering

Heavy machine tool air service

Serves a machining cell's clamps and actuated doors from a large plant-air takeoff, with the psi-scaled square gauge letting operators set and verify working pressure at the machine and the auto drain handling condensate.

Is the AirTAC GC600-25 FRL Unit (GC60025ALF2WTK) the Right Station?

Size and port are the first choice: this unit is size 600 with a 1 in NPT port, the largest step in the GC range, so match it to supply lines and expected air demand at that scale; smaller sizes 200/300/400 step down in port and flow. The 5 um element (code W) suits applications needing finer particulate removal than the 40 um standard. The automatic drain (code A) empties the bowl without manual attention - choose manual or differential-pressure drain only if you prefer a different service routine. The low-pressure regulator type is selected for circuits that work below standard regulated pressures; note the exact adjustment range for this low-pressure variant is not published, so confirm it with us. The square gauge here reads psi; MPa and bar scales are the other options, and an external round gauge is available. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Because flow for this series is published as curves and not as a single rated number, please ask us to confirm sizing against your actual air demand before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.

AirTAC GC600-25 FRL Unit (GC60025ALF2WTK) FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Tell us your application and line conditions and we will confirm the relevant datasheet flow-curve figures on request before you order.

In the code GC60025ALF2WTK, the A selects the automatic drain, which expels collected condensate from the bowl without anyone opening it - useful on large 600-size bowls in continuous service. The W selects the 5 um fine filter element instead of the 40 um standard, for cleaner air downstream. Both are configuration choices you can order differently on other GC600 variants.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC600-25 FRL Unit (GC60025ALF2WTK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC60025ALF2WTK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.