verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC600-25 FRL Unit (GC60025ANT)

The AirTAC GC600-25 FRL Unit (GC60025ANT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialAluminium alloy
  • Pressure gaugeNot fitted
  • ThreadNPT
$250.06 $257.56Save 2% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC600-25 drain, gauge and thread option on one page All GC600-25 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC600-25 FRL Unit (GC60025ANT)

GC60025ANT is an AirTAC G-series three-unit F.R.L. combination: separate filter, regulator and lubricator units assembled as one 3-piece set for 1 in NPT ports. The filter carries the standard 40 um element and the drain is automatic (A), expelling collected condensate without manual attention. The N in the code means no gauge is fitted, so regulated pressure is set against the plant's own instrumentation. The size 600 filter bowl is aluminium alloy.

This is a genuine AirTAC part for compressed air only, rated to 1.0 MPa (145 psi) maximum working pressure and operating from -5 to 70 C (non-freezing). The regulator adjustment range for this automatic-drain set-up is 0.15-0.9 MPa (20-130 psi). G (BSPP) and NPT threads are catalogue options, and flow is published as curves, so ask us to confirm datasheet figures on request.

AirTAC GC600-25 FRL Unit (GC60025ANT) Technical Specifications

ModelAirTAC GC600-25 FRL Unit (GC60025ANT)
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialAluminium alloy
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC600-25 FRL Unit (GC60025ANT)

GC600G-series F.R.L. combination, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT1" · 40 µm
One size downGC400
Two-unit equivalentGFC600-25
Build orderFilter → regulator → lubricator

Where the AirTAC GC600-25 FRL Unit (GC60025ANT) Is Used

handyman

Sawmill planer-mill air drops

Conditions the compressed-air drops feeding planer hold-down rolls and saw-guide cylinders, filtering, regulating and lubricating the supply with the automatic drain coping with the condensate of a long, humid mill main.

build

Quarry crusher plant circuits

Installed on the plant air feeding crusher clamp cylinders and dust-collector pulse duty, the set keeps grit-laden supply filtered to 40 um and regulated for the actuators, with no gauge where the control room already monitors pressure.

engineering

Shipyard outfitting workshop

Mounted on the compressed-air header of an outfitting workshop, it conditions air for hand tools and jigs across the bays, with the automatic drain removing moisture and the regulator set to suit the tool circuits.

Is the AirTAC GC600-25 FRL Unit (GC60025ANT) the Right Station?

Size 600 with 1 in NPT ports suits the largest G-series duties; step down to size 400 (3/4 in) or smaller when the line allows. This model omits the gauge - the right choice when a panel-mounted gauge or the plant PLC already reads pressure - while neighbouring codes add an embedded square gauge in MPa or psi or an external round gauge. Drain here is automatic; manual and differential-pressure versions exist if you prefer to control drain behaviour yourself.

Flow is published as curves, not a single rating, so ask us to confirm sizing against the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.

AirTAC GC600-25 FRL Unit (GC60025ANT) FAQ

AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not quote a number here. Share your line size and demand and we will confirm the sizing from the datasheet on request.

The drain can be automatic, manual or differential-pressure, and the gauge can be an embedded square gauge in MPa or psi, an external round gauge, or omitted entirely as on this N-coded model. Filter grade is 40 um standard or 5 um with W. All are decodable from the code itself.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC600-25 FRL Unit (GC60025ANT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC60025ANT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.