verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC600-25 FRL Unit (GC60025C1T)

The AirTAC GC600-25 FRL Unit (GC60025C1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$238.79 $246.29Save 3% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC600-25 drain, gauge and thread option on one page All GC600-25 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC600-25 FRL Unit (GC60025C1T)

GC60025C1T is an AirTAC G-series three-unit F.R.L. combination: separate filter, regulator and lubricator units assembled as one 3-piece set for 1 in NPT ports. The filter uses the standard 40 um element, the drain is the differential-pressure default (it passes condensate as flow-induced pressure difference builds), and an external round gauge scaled in MPa (C1) is fitted. The size 600 filter bowl is aluminium alloy.

This is a genuine AirTAC part for compressed air only, rated to 1.0 MPa (145 psi) maximum working pressure and operating from -5 to 70 C (non-freezing). The regulator adjustment range for this differential-pressure-drain set-up is 0.15-0.9 MPa (20-130 psi). G (BSPP) and NPT threads are catalogue options, and flow figures are published as curves, so ask us to confirm datasheet details on request.

AirTAC GC600-25 FRL Unit (GC60025C1T) Technical Specifications

ModelAirTAC GC600-25 FRL Unit (GC60025C1T)
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC600-25 FRL Unit (GC60025C1T)

GC600G-series F.R.L. combination, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT1" · 40 µm
One size downGC400
Two-unit equivalentGFC600-25
Build orderFilter → regulator → lubricator

Where the AirTAC GC600-25 FRL Unit (GC60025C1T) Is Used

settings_input_component

Paper mill winder controls

Conditions the compressed air feeding the winder's pneumatic control panels: filtered, regulated and lubricated supply to the positioner circuits, with the round MPa gauge matching the mill's metric instrumentation.

conveyor_belt

Cement packing line palletisers

Mounted ahead of the palletiser's cylinder bank on a packing line, the set filters plant air to 40 um, regulates it for the clamp and pusher actuators and lubricates them, with the differential-pressure drain working unattended.

science

Dairy plant CIP utility skid

Installed on the utility-air skid serving clean-in-place valve actuation in a dairy, it conditions the supply for hygienic valve tops, with the MPa-scaled round gauge giving operators a local set-point readout.

Is the AirTAC GC600-25 FRL Unit (GC60025C1T) the Right Station?

Size 600 with 1 in NPT ports is the largest G-series step; choose size 400 (3/4 in) or smaller where the line and demand allow. This model keeps the standard 40 um element and the differential-pressure drain - the catalogue default that needs no drain setting - and adds an external round MPa gauge, which suits panels that read in MPa. Codes in the same frame change the drain to automatic or manual, the element to 5 um, the gauge scale to psi, or drop the gauge.

Because flow is published as curves rather than a single rating, send us your duty and we will confirm the sizing from the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.

AirTAC GC600-25 FRL Unit (GC60025C1T) FAQ

AirTAC publishes G-series flow as curves, not as a single rating, so no one-number figure is quoted here. Tell us your line pressure and demand and we will confirm the sizing against the datasheet on request.

The differential-pressure drain is the catalogue default: condensate passes as the pressure difference across the filter builds during flow. The automatic-drain codes expel condensate on their own cycle, while manual-drain codes are emptied by hand. The regulator adjustment range is 0.15-0.9 MPa (20-130 psi) for the differential and automatic versions.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC600-25 FRL Unit (GC60025C1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC60025C1T and will confirm price, availability and lead time — usually within 7 hours.