AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC600-25 FRL Unit (GC60025MLC2WT)

The AirTAC GC600-25 FRL Unit (GC60025MLC2WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$238.79 $246.29Save 3% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC600-25 drain, gauge and thread option on one page All GC600-25 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC600-25 FRL Unit (GC60025MLC2WT)

The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator built as one set. This GC60025MLC2WT is the size 600 unit for 1 in. NPT1 threaded lines. The filter carries a 5 um element (code W) in an aluminium alloy bowl with a manual drain, so condensate is drained by hand on a schedule you control. The regulator is the L low-pressure type, fitted with an external round gauge reading in psi; its exact adjustment range is not published in our data, so confirm it with us if your set pressure is critical. A reverse (check) valve is not fitted, the maximum inlet pressure is 1.0 MPa (145 psi), operating temperature is -5 to 70 C non-freezing, and a mounting bracket is included.

This is a genuine AirTAC part. The GC range spans sizes 200, 300, 400 and 600 with ports from 1/8 in. up to 1 in., drain choices (differential-pressure, automatic or manual), 40 um standard or 5 um filtration, gauge and scale options, and three thread types (NPT on this code). Flow figures are published as curves rather than a single rating, so ask us to confirm the datasheet and sizing for your application before ordering.

AirTAC GC600-25 FRL Unit (GC60025MLC2WT) Technical Specifications

ModelAirTAC GC600-25 FRL Unit (GC60025MLC2WT)
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1" (NPT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialAluminium alloy
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC600-25 FRL Unit (GC60025MLC2WT)

GC600G-series F.R.L. combination, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT1" · 5 µm
One size downGC400
Two-unit equivalentGFC600-25
Build orderFilter → regulator → lubricator

Where the AirTAC GC600-25 FRL Unit (GC60025MLC2WT) Is Used

precision_manufacturing

CNC machining cell

Feeding filtered, regulated and lubricated air to pneumatic clamps and tool-change cylinders on a machining centre, with the 5 um element protecting downstream valves from fine particulate and rust scale.

factory

Automotive assembly stations

Supplying air to impact wrenches and air motors at assembly stations: the lubricator carries an oil mist to the tools while the regulator holds the working pressure the station was set up for.

conveyor_belt

Packaging conveyor line

Running pneumatic diverters, pushers and gripper cylinders on a bottling and packaging conveyor, with the manual-drain filter bowl checked and drained as part of routine shift maintenance.

Is the AirTAC GC600-25 FRL Unit (GC60025MLC2WT) the Right Station?

Size 600 with a 1 in. NPT port is the largest step in the GC range; choose size and port against the air demand of your line and let us check the published flow curves with you before you commit. Drain type is a real choice: this unit has a manual drain (code M), while differential-pressure (the default) and automatic drains are available on other GC codes. The W code selects the 5 um element instead of the 40 um standard. The gauge here is the external round type reading psi; embedded square gauges and MPa or bar scales are the other options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Because flow is published as curves rather than a single rating, send us your application details and we will confirm sizing from the datasheet.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.

AirTAC GC600-25 FRL Unit (GC60025MLC2WT) FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a number here. Tell us your line pressure and the air demand of your equipment, and we will confirm the sizing from the datasheet on request.

The M in the code selects a manual drain on the filter bowl: condensate is drained by hand during routine checks. Differential-pressure drain (the default) and automatic drain are available on other GC codes if you would rather not rely on manual draining.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC600-25 FRL Unit (GC60025MLC2WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC60025MLC2WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.