The AirTAC Airtac GF Filter GF200C06W is a genuine G-series air filter. It separates condensed water and filters particulate from the compressed-air line through a 40 µm element, with See datasheet ports and a differential-pressure drain. A filter does not set downstream pressure — pair it with a GR regulator, or use a GFR filter regulator, when pressure control is needed.
GF200C06W is a genuine AirTAC G-series air filter in the GF200 size - filtration only, with no pressure regulation and no lubrication. The 06 port decodes to PT1/8 with PT as the standard thread, and the W code fits the finer 5 um element instead of the 40 um standard. With no drain letter, this is the differential-pressure drain: the bowl bleeds condensate automatically as pressure drop across the element builds, with no operator input. The bracket is included. Because this is not the manual-drain version, the maximum inlet pressure is 1.0 MPa (145 psi), the 200-size bowl is polycarbonate, and the temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part from the GF series, which spans the 200/300/400/600 sizes with catalogue options for drain type (differential-pressure, automatic, manual), element grade (40 um standard, 5 um with W), G and NPT threads, and bracket choices. AirTAC publishes flow as curves rather than one rated figure, so ask us to confirm the datasheet numbers for your application.
| Model | Airtac GF Filter GF200C06W |
|---|---|
| Series | GF200 air filter |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Drain type | Differential-pressure drain |
| Bracket | Mounting bracket included |
| Fluid | Compressed air |
|---|---|
| Inlet pressure | 0.15 - 1.0 MPa (22 - 145 psi) |
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Bowl material | PC |
| Feature | Low pressure loss |
Specifications follow the official AirTAC G-series air-preparation data. The inlet-pressure band is set by the drain type: automatic and differential-pressure drains run 0.15 - 1.0 MPa, a manual drain runs 0 - 0.9 MPa. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GF200 | G-series air filter, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain. Options are differential (blank), automatic (A) or manual (M). |
| (blank) | Mounting bracket included. A bracket ships by default; J orders it without. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
Field order is size, port, drain, bracket, grade, thread — a blank position takes the default. Example: GF300-10AJW is a 300 body, PT3/8", automatic drain, no bracket, 5 µm element, PT thread.
A larger body carries a larger port and passes more air at the same pressure drop. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure. The GF600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GF200 · See datasheet · 40 µm |
|---|---|
| One size up | GF300 |
| Line order | Filter first, then regulator, then lubricator |
Mounted inside a control panel where nobody opens the door daily, filtering the 1/8 in air feed to panel pneumatics; the differential-pressure drain sheds condensate without scheduled manual bleeding.
Conditioning the fine air supply to registration and dampening actuator circuits on a press, where the 5 um element protects small pilot valves and the automatic drain action suits continuous running.
Cleaning air at the point of use on packaging and filling lines with frequent washdown access limits, keeping water and fine grit out of small cylinders while the bowl drains itself in service.
The differential-pressure drain is the hands-off choice: condensate is expelled as the element loads up, so the unit suits enclosed panels and hard-to-reach positions - and it keeps the full 1.0 MPa inlet rating that the manual-drain GF200 variants give up. The 5 um W element gives finer protection than the 40 um standard; pick 40 um where coarse pre-filtration is all you need. The PT1/8 port is the smallest step in the range, so upsize to GF300/400/600 as demand grows. PT thread is standard with G and NPT orderable, and the bracket comes included.
Flow is published only as curves, so we quote no single rating. Tell us your duty point and we will confirm the datasheet figures before you order.
Quick checklist
The PC bowl must not be cleaned with solvents or exposed to synthetic oils that attack polycarbonate — wipe it with a dry cloth. A filter removes water and particulate only; it does not regulate pressure or add lubrication.
AirTAC publishes filter flow as performance curves, not a single rated number, so we do not quote a figure here. Give us your line pressure and air demand and we will confirm the sizing against the official datasheet before you order.
With no drain letter in the code, the GF200C06W uses the default differential-pressure drain: as the element loads with contaminant and the pressure drop across it rises, the bowl expels collected condensate automatically. That keeps the full 1.0 MPa inlet rating and removes the manual bleeding the M-coded versions require. Manual and automatic drains are available as options on the same GF200 filter, along with the 40 um standard element if 5 um is finer than you need.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7-8 hours.