The AirTAC Airtac GF Filter GF200C08MW is a genuine G-series air filter. It separates condensed water and filters particulate from the compressed-air line through a 40 µm element, with See datasheet ports and a differential-pressure drain. A filter does not set downstream pressure — pair it with a GR regulator, or use a GFR filter regulator, when pressure control is needed.
GF200C08MW is an AirTAC GF-series air filter for compressed air. It filters water and particulate only - it neither regulates pressure nor lubricates. This unit is size 200 with a 1/4 inch PT (standard) port, a W-specified 5 um fine element, a manual drain, and a mounting bracket included. The 200-size bowl is polycarbonate (PC).
This is a genuine AirTAC part. The GF family is offered in sizes 200, 300, 400 and 600 with 40 um standard or 5 um elements, a choice of drain types, and PT (standard), G or NPT threads as catalogue options; larger 600 bowls are aluminium alloy. Maximum inlet pressure for this manual-drain filter is 0-0.9 MPa. Rated flow is published as curves, not a single figure, so we confirm sizing and datasheet data on request.
| Model | Airtac GF Filter GF200C08MW |
|---|---|
| Series | GF200 air filter |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Drain type | Differential-pressure drain |
| Bracket | Mounting bracket included |
| Fluid | Compressed air |
|---|---|
| Inlet pressure | 0.15 - 1.0 MPa (22 - 145 psi) |
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Bowl material | PC |
| Feature | Low pressure loss |
Specifications follow the official AirTAC G-series air-preparation data. The inlet-pressure band is set by the drain type: automatic and differential-pressure drains run 0.15 - 1.0 MPa, a manual drain runs 0 - 0.9 MPa. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GF200 | G-series air filter, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain. Options are differential (blank), automatic (A) or manual (M). |
| (blank) | Mounting bracket included. A bracket ships by default; J orders it without. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
Field order is size, port, drain, bracket, grade, thread — a blank position takes the default. Example: GF300-10AJW is a 300 body, PT3/8", automatic drain, no bracket, 5 µm element, PT thread.
A larger body carries a larger port and passes more air at the same pressure drop. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure. The GF600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GF200 · See datasheet · 40 µm |
|---|---|
| One size up | GF300 |
| Line order | Filter first, then regulator, then lubricator |
Mount this bracketed filter at a paint-booth air drop feeding spray guns, where the 5 um element keeps fine particles out of the finish and the manual drain is bled at the start of each coating session.
Install on the 1/4 inch supply to guide-rail adjusters and stopper cylinders along a bottling conveyor. Filtered 5 um air protects the small control valves, and the bracket fixes the unit to the conveyor frame.
Use on an engineering test bench supplying gauges, transducers and small pneumatic actuators, where the fine element prevents particulate from skewing readings and the manual drain clears accumulated water after each test run.
This configuration pairs the 5 um W element with the manual drain and a supplied bracket, so it can be screwed to a frame or wall beside the point of use. Size 200 with a 1/4 inch PT port suits individual machines and branch lines; step to 300, 400 or 600 for larger ports and more flow. Manual drain suits stations on a regular maintenance route - pick automatic drain for hard-to-reach spots. Thread is PT as standard with G (BSPP) and NPT as order options.
GF-series flow is published as curves rather than a single rated number, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents or exposed to synthetic oils that attack polycarbonate — wipe it with a dry cloth. A filter removes water and particulate only; it does not regulate pressure or add lubrication.
Yes - on request. AirTAC publishes GF-series flow as curves across the pressure range rather than a single rated figure, so we do not print a number here. Send us your line pressure and the air demand of the equipment, and we will confirm from the datasheet that size 200 at 1/4 inch is the right choice.
In GF200C08MW the M position selects the manual drain: collected water is released by hand, which suits stations visited on a maintenance route. The differential-pressure drain (the code default) and the automatic drain suit locations where nobody regularly tends the unit. All three share the same 5 um filtration, 1/4 inch PT port and bracket here.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7-8 hours.