verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GF300 · Air Filter (water separation + particulate filtration)

Airtac GF Filter GF300C10MJW

The AirTAC Airtac GF Filter GF300C10MJW is a genuine G-series air filter. It separates condensed water and filters particulate from the compressed-air line through a 40 µm element, with See datasheet ports and a differential-pressure drain. A filter does not set downstream pressure — pair it with a GR regulator, or use a GFR filter regulator, when pressure control is needed.

  • TypeAir filter
  • Port sizeSee datasheet
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Inlet pressure0.15 - 1.0 MPa (22 - 145 psi)
  • Bowl materialPC
  • ThreadPT
  • BracketMounting bracket included
$32.08 $36.56Save 12% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GF300 stroke, mounting and version on one page All GF300 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GF Filter GF300C10MJW

The AirTAC GF300C10MJW is a G-series air filter providing filtration only - it removes water and particulate from compressed air, with no regulator and no lubricator. The W suffix fits the fine 5 um element instead of the standard 40 um, catching smaller particles ahead of sensitive pneumatic equipment. This size 300 unit has PT3/8 ports, a manual drain (inlet range 0-0.9 MPa / 0-130 psi) and, per the J suffix, is supplied without a mounting bracket.

This is a genuine AirTAC part. GF filters are available in sizes 200, 300, 400 and 600 with differential-pressure, automatic or manual drains, 40 um standard or 5 um (W) elements, and PT as the standard thread with G (BSPP) and NPT catalogue options. Flow is published as curves, not a single rating, so we confirm the datasheet and sizing on request.

Airtac GF Filter GF300C10MJW Technical Specifications

ModelAirtac GF Filter GF300C10MJW
SeriesGF300 air filter
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Drain typeDifferential-pressure drain
BracketMounting bracket included
FluidCompressed air
Inlet pressure0.15 - 1.0 MPa (22 - 145 psi)
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Bowl materialPC
FeatureLow pressure loss

Specifications follow the official AirTAC G-series air-preparation data. The inlet-pressure band is set by the drain type: automatic and differential-pressure drains run 0.15 - 1.0 MPa, a manual drain runs 0 - 0.9 MPa. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GF Filter GF300C10MJW

GF300G-series air filter, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain. Options are differential (blank), automatic (A) or manual (M).
(blank)Mounting bracket included. A bracket ships by default; J orders it without.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.

Field order is size, port, drain, bracket, grade, thread — a blank position takes the default. Example: GF300-10AJW is a 300 body, PT3/8", automatic drain, no bracket, 5 µm element, PT thread.

Size Class

  • GF200PT1/8" - PT1/4"
  • GF300PT1/4" - PT1/2"
  • GF400PT3/8" - PT1/2"
  • GF600PT3/4" - PT1"

A larger body carries a larger port and passes more air at the same pressure drop. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure. The GF600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGF300 · See datasheet · 40 µm
One size downGF200
One size upGF400
Line orderFilter first, then regulator, then lubricator

Where the Airtac GF Filter GF300C10MJW Is Used

science

Lab pneumatic instrument supply

Fine 5 um filtration on the 3/8" air feed to laboratory actuators, sample-handling cylinders and pneumatic test benches where dust carry-over from plant air is not acceptable.

air

Pneumatic conveyor air knife feed

Filtering the 3/8" supply to air knives and blow-off nozzles on a packaging or bottling line, so nozzle orifices stay clear of scale and the manual drain is emptied on the cleaning round.

build

Robot gripper circuit conditioning

Point-of-use conditioning ahead of pick-and-place robot gripper valves on an automation cell, protecting small orifices and seals from particulate in the 3/8" branch line.

Is the Airtac GF Filter GF300C10MJW the Right Filter?

The key choice here is filtration grade: the 5 um W element suits air feeding precision valves, measuring circuits and coating equipment, while the standard 40 um grade is enough for rough utility air. Size by demand - 300 with 3/8" ports is the mid frame; go smaller or larger as the circuit requires. Manual drain (this model) needs routine attention; choose automatic (A) or differential-pressure (blank) for unattended drainage. Thread is PT standard, with G and NPT orderable; this J version omits the bracket.

Flow appears in the catalogue only as curves, so ask us to confirm sizing against your application from the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain: differential, automatic or manual
  • ✓ Manual drain caps inlet at 0.9 MPa
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Bracket needed, or order with J
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, and follow the airflow arrow.
  • check Put the filter first in the air-preparation line.
  • check Keep inlet pressure within 0.15 - 1.0 MPa (22 - 145 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Replace the 40 µm element when pressure loss rises.

The PC bowl must not be cleaned with solvents or exposed to synthetic oils that attack polycarbonate — wipe it with a dry cloth. A filter removes water and particulate only; it does not regulate pressure or add lubrication.

Airtac GF Filter GF300C10MJW FAQ

AirTAC publishes flow as curves rather than one rated figure, so we do not state a number here. We can check the GF300 curve set against your pressure and demand and confirm sizing from the datasheet on request before you order.

Choose the W element when downstream equipment - precision valves, instrumentation, coating or measuring devices - needs finer particulate removal than general plant air. Note the 5 um element will need checking more often; and if you also need pressure control, that is a separate regulator or a GFR filter-regulator, since the GF filters only.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GF Filter GF300C10MJW

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GF300C10MJW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.