The AirTAC Airtac GF Filter GF400C10MW is a genuine G-series air filter. It separates condensed water and filters particulate from the compressed-air line through a 40 µm element, with See datasheet ports and a differential-pressure drain. A filter does not set downstream pressure — pair it with a GR regulator, or use a GFR filter regulator, when pressure control is needed.

  • TypeAir filter
  • Port sizeSee datasheet
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Inlet pressure0.15 - 1.0 MPa (22 - 145 psi)
  • Bowl materialPC
  • ThreadPT
  • BracketMounting bracket included
$46.81 $51.66Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GF400 stroke, mounting and version on one page All GF400 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GF Filter GF400C10MW

GF400C10MW is an AirTAC G-series air filter: it removes water and particulate from compressed air only - it does not regulate pressure and it does not lubricate. This 400-size unit has a 3/8 in PT port, a fine 5 um element (the tighter of the two catalogue grades), a manual drain on the polycarbonate bowl, and a mounting bracket is included. Working temperature is -5 to 70 C (non-freezing); with the manual drain the inlet pressure range is 0-0.9 MPa.

This is a genuine AirTAC part. The GF filter family runs in sizes 200, 300, 400 and 600, with 40 um standard or 5 um (W) filtration, differential-pressure, automatic or manual drains, and PT as the standard thread with G (BSPP) and NPT as catalogue options. AirTAC publishes filter flow as curves rather than a single rating, so we confirm the datasheet and sizing on request.

Airtac GF Filter GF400C10MW Technical Specifications

ModelAirtac GF Filter GF400C10MW
SeriesGF400 air filter
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Drain typeDifferential-pressure drain
BracketMounting bracket included
FluidCompressed air
Inlet pressure0.15 - 1.0 MPa (22 - 145 psi)
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Bowl materialPC
FeatureLow pressure loss

Specifications follow the official AirTAC G-series air-preparation data. The inlet-pressure band is set by the drain type: automatic and differential-pressure drains run 0.15 - 1.0 MPa, a manual drain runs 0 - 0.9 MPa. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GF Filter GF400C10MW

GF400G-series air filter, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain. Options are differential (blank), automatic (A) or manual (M).
(blank)Mounting bracket included. A bracket ships by default; J orders it without.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.

Field order is size, port, drain, bracket, grade, thread — a blank position takes the default. Example: GF300-10AJW is a 300 body, PT3/8", automatic drain, no bracket, 5 µm element, PT thread.

Size Class

  • GF200PT1/8" - PT1/4"
  • GF300PT1/4" - PT1/2"
  • GF400PT3/8" - PT1/2"
  • GF600PT3/4" - PT1"

A larger body carries a larger port and passes more air at the same pressure drop. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure. The GF600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGF400 · See datasheet · 40 µm
One size downGF300
One size upGF600
Line orderFilter first, then regulator, then lubricator

Where the Airtac GF Filter GF400C10MW Is Used

precision_manufacturing

CNC machining centre air supply

Point-of-use conditioning for the machine's clamping and air-blow circuits, where the 5 um element keeps fine particulate out of downstream valves and the manual drain is emptied at shift checks.

science

Laboratory pneumatic test bench

Cleaning the shop-air feed to a QA or R&D test bench where the finer 5 um grade protects sensitive instruments and a manual drain suits intermittent, attended use.

build

Pneumatic tool air drops

A workshop drop filter ahead of impact wrenches, grinders and couplings, catching water and pipe scale before it reaches the tools and hoses.

Is the Airtac GF Filter GF400C10MW the Right Filter?

Step up or down through sizes 200/300/400/600 to match the port and flow your line needs - 400 with a 3/8 in PT port suits mid-size machine supplies. Choose the drain to match servicing: manual (this code, with its 0-0.9 MPa inlet range), automatic, or the default differential-pressure type. Pick the 5 um (W) grade when downstream equipment needs finer air than the standard 40 um element. Thread is PT as standard; G and NPT are orderable options, and a bracket is included here. Because flow is published as curves, not a single rated figure, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain: differential, automatic or manual
  • ✓ Manual drain caps inlet at 0.9 MPa
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Bracket needed, or order with J
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, and follow the airflow arrow.
  • check Put the filter first in the air-preparation line.
  • check Keep inlet pressure within 0.15 - 1.0 MPa (22 - 145 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Replace the 40 µm element when pressure loss rises.

The PC bowl must not be cleaned with solvents or exposed to synthetic oils that attack polycarbonate — wipe it with a dry cloth. A filter removes water and particulate only; it does not regulate pressure or add lubrication.

Airtac GF Filter GF400C10MW FAQ

AirTAC publishes filter capacity as flow curves, not a single rated figure, so we do not quote a number here. Request the datasheet and we will confirm the flow curve and check this 3/8 in, 400-size unit against your application before you order.

The M in this code means the polycarbonate bowl has a manual drain: someone drains it at service intervals, and the inlet pressure range is 0-0.9 MPa. If the unit sits in a hard-to-reach spot or runs unattended, ask instead for the automatic (A) or differential-pressure (blank) drain version of the same filter.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GF Filter GF400C10MW

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GF400C10MW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.