verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GF400 · Air Filter (water separation + particulate filtration)

Airtac GF Filter GF400C15M

The AirTAC Airtac GF Filter GF400C15M is a genuine G-series air filter. It separates condensed water and filters particulate from the compressed-air line through a 40 µm element, with See datasheet ports and a differential-pressure drain. A filter does not set downstream pressure — pair it with a GR regulator, or use a GFR filter regulator, when pressure control is needed.

  • TypeAir filter
  • Port sizeSee datasheet
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Inlet pressure0.15 - 1.0 MPa (22 - 145 psi)
  • Bowl materialPC
  • ThreadPT
  • BracketMounting bracket included
$46.81 $51.66Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GF400 stroke, mounting and version on one page All GF400 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GF Filter GF400C15M

GF400C15M is an AirTAC G-series air filter that removes water and particulate from compressed air only - it provides no regulation and no lubrication. The 400 frame takes a PT1/2 port, the standard element grade is 40 um, and the M code specifies a manual drain that you open yourself to empty collected condensate, with a 0 to 0.9 MPa inlet range. The mounting bracket is included as standard. The polycarbonate bowl suits the -5 to 70 C operating window.

This is a genuine AirTAC part from the G series, offered in 200, 300, 400 and 600 frame sizes with a choice of differential-pressure, automatic or manual drains, 40 um or 5 um elements, and G (BSPP) or NPT threads as alternatives to the standard PT. Flow appears in the catalogue as curves rather than a single rated figure, so ask us to confirm the datasheet and check sizing for your line before ordering.

Airtac GF Filter GF400C15M Technical Specifications

ModelAirtac GF Filter GF400C15M
SeriesGF400 air filter
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Drain typeDifferential-pressure drain
BracketMounting bracket included
FluidCompressed air
Inlet pressure0.15 - 1.0 MPa (22 - 145 psi)
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Bowl materialPC
FeatureLow pressure loss

Specifications follow the official AirTAC G-series air-preparation data. The inlet-pressure band is set by the drain type: automatic and differential-pressure drains run 0.15 - 1.0 MPa, a manual drain runs 0 - 0.9 MPa. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GF Filter GF400C15M

GF400G-series air filter, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain. Options are differential (blank), automatic (A) or manual (M).
(blank)Mounting bracket included. A bracket ships by default; J orders it without.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.

Field order is size, port, drain, bracket, grade, thread — a blank position takes the default. Example: GF300-10AJW is a 300 body, PT3/8", automatic drain, no bracket, 5 µm element, PT thread.

Size Class

  • GF200PT1/8" - PT1/4"
  • GF300PT1/4" - PT1/2"
  • GF400PT3/8" - PT1/2"
  • GF600PT3/4" - PT1"

A larger body carries a larger port and passes more air at the same pressure drop. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure. The GF600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGF400 · See datasheet · 40 µm
One size downGF300
One size upGF600
Line orderFilter first, then regulator, then lubricator

Where the Airtac GF Filter GF400C15M Is Used

settings_input_component

Carton sealer pneumatic circuit

Fitted ahead of the cylinder and valve bank on a packaging-line carton sealer, the 40 um element catches pipe scale and condensate that would otherwise cause sluggish stroking and valve wear.

factory

Plant air main drop filtration

Installed at a work-area drop off a factory air main, the manual drain lets maintenance staff empty collected water at the start of each shift, protecting every tool and cylinder hung downstream.

handyman

Maintenance shop air ring main

On a maintenance workshop's ring main serving impact wrenches and air ratchets, the filter keeps grit and moisture out of the tools, and the included bracket fixes it neatly to the wall or bench frame.

Is the Airtac GF Filter GF400C15M the Right Filter?

Pick the frame size - 200, 300, 400 or 600 - to match the port and the demand of the line; this 400 unit with PT1/2 ports covers mid-to-large plant circuits. The standard 40 um element suits general protection of cylinders, valves and tools; specify the W version for a finer 5 um grade. This model's manual drain (M) suits positions a technician visits routinely; choose differential-pressure (blank) or automatic (A) drains where hands-off condensate removal matters. Threads are standard PT, with G (BSPP) and NPT to order, and the bracket is included. Flow is published as curves, not one rating, so ask us to confirm sizing from the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain: differential, automatic or manual
  • ✓ Manual drain caps inlet at 0.9 MPa
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Bracket needed, or order with J
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, and follow the airflow arrow.
  • check Put the filter first in the air-preparation line.
  • check Keep inlet pressure within 0.15 - 1.0 MPa (22 - 145 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Replace the 40 µm element when pressure loss rises.

The PC bowl must not be cleaned with solvents or exposed to synthetic oils that attack polycarbonate — wipe it with a dry cloth. A filter removes water and particulate only; it does not regulate pressure or add lubrication.

Airtac GF Filter GF400C15M FAQ

There is no single rated flow figure for this filter - AirTAC publishes G-series flow as performance curves. Send us your operating pressure and flow requirement and we will confirm the datasheet figures and check the frame size for you on request.

A manual drain (M) is emptied by hand, which suits supervised positions visited regularly, and its inlet range is 0 to 0.9 MPa. If nobody attends the point regularly, choose the differential-pressure drain (blank code) or the automatic drain (A) so condensate is shed without operator action.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GF Filter GF400C15M

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GF400C15M and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.