verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GF400 · Air Filter (water separation + particulate filtration)

Airtac GF Filter GF400C15MJW

The AirTAC Airtac GF Filter GF400C15MJW is a genuine G-series air filter. It separates condensed water and filters particulate from the compressed-air line through a 40 µm element, with See datasheet ports and a differential-pressure drain. A filter does not set downstream pressure — pair it with a GR regulator, or use a GFR filter regulator, when pressure control is needed.

  • TypeAir filter
  • Port sizeSee datasheet
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Inlet pressure0.15 - 1.0 MPa (22 - 145 psi)
  • Bowl materialPC
  • ThreadPT
  • BracketMounting bracket included
$45.70 $50.52Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GF400 stroke, mounting and version on one page All GF400 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GF Filter GF400C15MJW

GF400C15MJW is an AirTAC G-series air filter whose sole function is removing water and particulate from compressed air - it does not regulate pressure and does not lubricate. The 400 frame takes a PT1/2 port, the W code selects the finer 5 um element in place of the 40 um standard, and the M code provides a manual drain you operate yourself, with a 0 to 0.9 MPa inlet range. The J code omits the mounting bracket. The polycarbonate bowl is rated for the -5 to 70 C operating window.

This is a genuine AirTAC part from the G series, which runs in 200, 300, 400 and 600 frame sizes with a choice of differential-pressure, automatic or manual drains, 40 um or 5 um elements, G (BSPP) or NPT threads, and a bracket where required. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and check the sizing against your application before ordering.

Airtac GF Filter GF400C15MJW Technical Specifications

ModelAirtac GF Filter GF400C15MJW
SeriesGF400 air filter
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Drain typeDifferential-pressure drain
BracketMounting bracket included
FluidCompressed air
Inlet pressure0.15 - 1.0 MPa (22 - 145 psi)
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Bowl materialPC
FeatureLow pressure loss

Specifications follow the official AirTAC G-series air-preparation data. The inlet-pressure band is set by the drain type: automatic and differential-pressure drains run 0.15 - 1.0 MPa, a manual drain runs 0 - 0.9 MPa. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GF Filter GF400C15MJW

GF400G-series air filter, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain. Options are differential (blank), automatic (A) or manual (M).
(blank)Mounting bracket included. A bracket ships by default; J orders it without.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.

Field order is size, port, drain, bracket, grade, thread — a blank position takes the default. Example: GF300-10AJW is a 300 body, PT3/8", automatic drain, no bracket, 5 µm element, PT thread.

Size Class

  • GF200PT1/8" - PT1/4"
  • GF300PT1/4" - PT1/2"
  • GF400PT3/8" - PT1/2"
  • GF600PT3/4" - PT1"

A larger body carries a larger port and passes more air at the same pressure drop. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure. The GF600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGF400 · See datasheet · 40 µm
One size downGF300
One size upGF600
Line orderFilter first, then regulator, then lubricator

Where the Airtac GF Filter GF400C15MJW Is Used

science

Laboratory pneumatic supply

On a lab's compressed-air ring feeding benchtop instruments and actuated fittings, the 5 um element removes fine particles that coarse filters pass, and the manual drain is emptied during routine lab checks.

air

Textile air-jet loom supply

Ahead of the air jets on a weaving shed's looms, the 5 um grade helps keep jet orifices clear of particulate, with the manual drain bled off each shift to control accumulated condensate.

tune

Instrument air take-off in a process skid

Installed on the instrument-air take-off of a process skid, the filter's fine 5 um element guards positioners and small-bore fittings from particle fouling while the manual drain handles collected water.

Is the Airtac GF Filter GF400C15MJW the Right Filter?

Select the frame size - 200, 300, 400 or 600 - against port size and demand; the 400 body with PT1/2 ports serves mid-to-large air lines. This model's 5 um element (W) is the finer option for protecting sensitive valves and instruments, while the standard grade is 40 um. The manual drain (M) suits accessible, regularly serviced points; differential-pressure (blank) and automatic (A) drains cover unattended ones. Threads are standard PT, with G (BSPP) and NPT available to order, and the J code deletes the bracket for inline mounting. Because AirTAC publishes flow as curves, not a single rating, ask us to confirm sizing from the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain: differential, automatic or manual
  • ✓ Manual drain caps inlet at 0.9 MPa
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Bracket needed, or order with J
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, and follow the airflow arrow.
  • check Put the filter first in the air-preparation line.
  • check Keep inlet pressure within 0.15 - 1.0 MPa (22 - 145 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Replace the 40 µm element when pressure loss rises.

The PC bowl must not be cleaned with solvents or exposed to synthetic oils that attack polycarbonate — wipe it with a dry cloth. A filter removes water and particulate only; it does not regulate pressure or add lubrication.

Airtac GF Filter GF400C15MJW FAQ

No single rated flow figure applies - AirTAC publishes G-series flow as performance curves. Give us your line pressure and demand and we will confirm the datasheet figures and verify that this 400 frame is correctly sized on request.

The standard GF element grade is 40 um; the W code fits a 5 um element that captures much finer particles for sensitive downstream equipment. If general protection of cylinders and tools is all you need, the 40 um standard grade is usually the simpler choice.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GF Filter GF400C15MJW

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GF400C15MJW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.