The AirTAC AirTAC GFC200-06 Combination Unit (GFC20006C1K) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/8" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The GFC20006C1K is an AirTAC G-series two-unit set: a filter regulator plus a separate lubricator, so it filters, regulates and lubricates the compressed air in one purchase. This configuration is the compact 200 size with 1/8 in PT ports, a differential-pressure drain on the filter bowl, the standard 40 um filter element and the standard regulator type. It is fitted with a round external pressure gauge on the MPa scale and a reverse (check) valve. The 200-size bowls are polycarbonate (PC).
This is a genuine AirTAC part. The GFC family is offered in 200/300/400/600 sizes with 1/8 in to 1 in ports, manual, automatic or differential-pressure drains, 40 um or 5 um elements, gauge and thread options. Maximum working pressure is 1.0 MPa (145 psi) and with this differential-pressure drain the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi). Flow figures are published as curves, so we confirm datasheet and sizing figures on request.
| Model | AirTAC GFC200-06 Combination Unit (GFC20006C1K) |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-06 filter regulator and GL200-06 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-06 |
| Build order | Filter regulator first, lubricator last |
Mounted at a light-duty clamping station, the set dries the air, sets a stable working pressure and meters oil mist to keep the clamp cylinder seals lubricated.
Installed at an electronics assembly bench, it conditions the feed to small air screwdrivers, protecting them from dirt while delivering lubricating mist.
Fitted on the manifold feed of a small pick-and-place module, it regulates supply pressure to the gripper valves and oils the actuator air path.
The 200 size with 1/8 in PT ports suits compact circuits and small cylinders; step up to 300/400 when flow demand or port size grows. Drain choice is real: differential-pressure (this code) for automatic condensate bleeding, or manual for dry, intermittent lines. The 40 um element is the standard choice; order the W variant for 5 um. Gauge is the round external type on MPa scale here, and the K code adds a check valve that holds downstream pressure. PT is the standard thread, with G and NPT as catalogue options.
Flow for this set is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-06 filter regulator on its own.
AirTAC publishes flow for the G series as characteristic curves rather than a single rated figure, so no rated number is quoted here. Send us your flow requirement and we will confirm the datasheet curve for the 200 size before you order.
K means a reverse (check) valve is fitted in the regulator, which helps hold downstream pressure if the upstream supply drops. It is optional on GFC sets, so order this code only when your circuit needs that back-flow protection; without K the set is otherwise identical.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.