The AirTAC Airtac GFR Filter Regulator GFR200C08MN is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
GFR200C08MN is a genuine AirTAC G-series filter regulator: filtration and pressure regulation combined in one body, with no lubricator. This configuration is the 200 size with a 1/4" PT port, a manual-drain bowl in PC (polycarbonate), and the standard 40 um filter element for general plant air. A mounting bracket is included; no gauge is fitted, though the embedded square gauge is available as a catalogue option.
The GFR series spans 200, 300, 400 and 600 sizes with ports from 1/8" to 1", G(BSPP) and NPT thread options, and differential-pressure, automatic or manual drains. This unit carries a 1.0 MPa (145 psi) maximum inlet pressure, a manual-drain regulation range of 0.05-0.9 MPa (7-130 psi), and a -5 to 70 C (non-freezing) operating temperature. Flow is published as curves rather than a single rating, so we confirm flow and datasheet figures on request.
| Model | Airtac GFR Filter Regulator GFR200C08MN |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
A 1/4" conditioned drop at a plant maintenance bench: clean, regulated air for impact tools, blow-off guns and test rigs, with the bracket mounting the unit beside the coupler panel.
Feeding hose reels and tire-cage circuits in a commercial-vehicle service bay; the 40 um element and manual drain suit air that is already dried at the compressor room.
Regulating the plant air feeding cylinders and vacuum cups on a cartoning machine; the bracket fixes the unit to the machine frame next to the main shut-off valve.
This is the standard-filtration build of the 200 size at 1/4" PT: the 40 um element suits general plant air feeding cylinders, valves and air tools, while finer equipment calls for the 5 um W variant instead. The manual drain fits attended points of use with a routine bowl bleed; choose automatic (A) or the differential-pressure default for unattended lines, noting manual-drain builds carry the wider 0.05-0.9 MPa (7-130 psi) regulation range. The bracket is included, so the unit can be mounted beside the shut-off valve rather than hanging on the pipework. Thread is PT as standard, with G(BSPP) and NPT as catalogue options. Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your air demand before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
There is no single rated flow figure for this series - AirTAC publishes flow as curves. We do not quote a number here; instead, send your supply pressure and air consumption and we will confirm the correct size from the datasheet curves on request before you order.
The 40 um element (blank grade code) is the standard choice for general plant air feeding cylinders, valves and air tools; the 5 um W option is reserved for finer downstream equipment and needs more frequent draining. This model is the 40 um build with a manual drain and mounting bracket included - if your process needs finer filtration, order the W variant of the same 200-size, 1/4" PT unit.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.