The AirTAC Airtac GFR Filter Regulator GFR300C10AJC1W is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR series combines compressed-air filtration and pressure regulation in a single body. This GFR300 configuration is sized for a 3/8 in. PT port and carries the W-coded 5 um filter element for finer pre-filtration than the standard 40 um grade, with an automatically draining polycarbonate bowl so condensate leaves the unit without manual attention. Pressure is set on the built-in regulator and read on the external round gauge scaled in MPa. Rated inlet pressure is 1.0 MPa (145 psi) and the working range is -5 to 70 C.
This is a genuine AirTAC part in the 300 size of the G series (sizes 200, 300, 400 and 600). Automatic, manual and differential-pressure drains, 40 um and 5 um elements, round or square gauges in MPa, psi or bar scales, G (BSPP) and NPT threads and a reverse-flow valve are all catalogue options. Flow is published as curves rather than a single rating, so we confirm datasheet figures for your application on request.
| Model | Airtac GFR Filter Regulator GFR300C10AJC1W |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C1 (two-unit set) |
Pre-filtration and pressure regulation ahead of analytical instruments and pneumatic actuators in a lab or pilot plant, with automatic draining so the fine element is protected without daily attention.
Feeding banks of solenoid valves where the 5 um element helps keep particulate out of valve spools while the regulator holds their rated working pressure.
Conditioning supply air at a maintenance bench for grinders and impact tools, with pressure set on the round MPa gauge to suit each tool.
Sizes 200, 300, 400 and 600 step up in port and flow; this unit carries a 3/8 in. PT port. With automatic drain the regulator adjusts 0.15-0.9 MPa (20-130 psi); a manual-drain version widens the low end to 0.05 MPa. The W in this code selects the 5 um element over the 40 um standard - pick 5 um ahead of valves and instruments, 40 um for general line protection. Gauges are the embedded square type or an external round gauge with MPa, psi or bar scales. Threads order as PT (standard), G (BSPP) or NPT, and J omits the mounting bracket. Flow is published as curves, not a single rating, so ask us to confirm sizing before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series flow as curves, not as a single rated figure, so we do not state a number here. Share your line pressure and demanded flow and we will confirm sizing against the datasheet on request before you order.
The W code selects the 5 um element, suited to finer pre-filtration ahead of solenoid valves, instruments and other sensitive downstream equipment; the blank (40 um) grade suits general line protection. Both fit the same 300-size body, which is also offered with manual or differential-pressure drains, square or round gauges and G or NPT threads.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.