The AirTAC Airtac GFR Filter Regulator GFR300C10MJN is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR300C10MJN is a 300-size AirTAC filter regulator: filtration and pressure regulation in one body, with a 3/8in PT port as standard (G/BSPP and NPT are orderable thread options). The M code selects a manual drain on the polycarbonate bowl, and the standard element grade is 40 um. The N code means no pressure gauge is fitted, so a separate gauge is needed where a visual setpoint is required, and J means the mounting bracket is not supplied. Supply pressure is rated to 1.0 MPa (145 psi) and, with this manual-drain version, the outlet adjusts from 0.05 to 0.9 MPa (7-130 psi). Operating temperature is -5 to 70 C, non-freezing.
This is a genuine AirTAC part in the GFR300 series. The G platform runs from 200 to 600 size with ports from 1/8in to 1in, drain choices (differential-pressure, automatic, manual), 40 um or 5 um filtration, gauge and bracket options, and a low-pressure type on request. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.
| Model | Airtac GFR Filter Regulator GFR300C10MJN |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C1 (two-unit set) |
Feeds the solenoid valves cycling diverter gates on a filler conveyor, cleaning 40 um-grade shop air and setting a stable line pressure for repeatable gate timing.
Conditions the supply feeding clutch, brake and counterbalance circuits on a stamping press, keeping water and scale out of the downstream valves.
Supplies the stopper and gate cylinders along a pallet transport line, with the regulator set once for consistent actuation at each station.
Match the size (200 to 600) to your port and flow path; 300 with a 3/8in PT port suits mid-range circuits. Flow is published as curves, not a single rating, so share your demand and we will confirm sizing against the datasheet before you order. Manual drain suits installations with regular operator checks; pick an automatic or differential-pressure drain for unattended duty. The 40 um element is the standard grade for general shop-air protection; the W variant gives 5 um where finer filtration matters. If you need a setpoint readout, order a gauge variant (embedded square, or external round, in MPa, psi or bar scales) instead of the N suffix. PT is the standard thread - order G (BSPP) or NPT explicitly - and add a bracket if the unit is not panel- or wall-adjacent.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
Flow for this series is published as curves, not a single rated figure, so there is no one number we can quote. Send us your air demand and port size and we will confirm the datasheet figures and correct 300-size selection on request.
N means no pressure gauge is fitted. If you want a visual setpoint at the regulator, choose a variant with the embedded square gauge or an external round gauge, available in MPa, psi or bar scales.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.