The AirTAC Airtac GFR Filter Regulator GFR300C15MF1W is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
GFR300C15MF1W is an AirTAC GFR300 filter regulator: filtering and pressure regulation combined in one body, sized 300 with a 1/2 in PT port. The W code fits the finer 5 um filter element instead of the standard 40 um grade, and this configuration also carries a manual drain and a square pressure gauge on an MPa scale. It runs on compressed air only, from -5 to 70 C, with a maximum inlet pressure of 1.0 MPa (145 psi) and a regulator setting range of 0.05-0.9 MPa (7-130 psi) on this manual-drain version. The 300-size bowl is polycarbonate; only the 600 size carries an aluminium bowl.
This is a genuine AirTAC part sold by a distributor. The G series covers sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and drain types, filter grades, gauge styles and G (BSPP) or NPT threads are catalogue options. Flow is published as curves rather than a single rating, so we confirm the datasheet and full flow curve for your application on request.
| Model | Airtac GFR Filter Regulator GFR300C15MF1W |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C1 (two-unit set) |
The 5 um element removes finer particles ahead of sensitive instrument pneumatics, with pressure set and read on the square gauge.
Regulated, finely filtered air drives the sealing and clamping cylinders, with the bowl drained at each sanitation stop.
A stable regulated supply at the 1/2 in port supports repeatable test conditions, and the 5 um grade protects prototype tooling and valves.
Size 300 with a 1/2 in PT port is the mid-range choice in the G series; move up to 400 or 600 for larger ports and demand, or down to 200 for compact circuits. The W code selects the 5 um element - the right call when downstream equipment is sensitive to fine particles; the standard grade is 40 um. Manual drain keeps things simple but requires periodic opening of the bowl drain, so specify the automatic-drain code for unattended installations. The square MPa gauge is fitted, and PT is the standard thread with G (BSPP) and NPT available as ordered options. A bracket is included; J-coded versions omit it. Flow is published as curves, not one number - ask us to confirm sizing against your demand before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR300 series as curves rather than a single rated figure, so we do not state one number. Share your working pressure and required flow and we will confirm the datasheet and full flow curve for this 1/2 in port model on request before you order.
No. W only selects the 5 um element in place of the standard 40 um grade. Function, drain type, gauge, port and thread stay as specified here: filter regulator, manual drain, square MPa gauge, 1/2 in PT port. There is no lubricator in any GFR model - add a separate lubricator if oil mist is needed.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.